Miller STR 400 Owner'S Manual Download Page 5

OM-264 278 Page 1

SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING

som 2011−10

7

Protect yourself and others from injury —

 

read, follow, and save these important safety precautions and operating instructions.

1-1.

Symbol Usage

DANGER! − Indicates a hazardous situation which, if
not avoided, will result in death or serious injury. The
possible hazards are shown in the adjoining symbols
or explained in the text.

Indicates a hazardous situation which, if not avoided,
could result in death or serious injury. The possible
hazards are shown in the adjoining symbols or ex-
plained in the text.

NOTICE − Indicates statements not related to personal injury.

Indicates special instructions.

This group of symbols means Warning! Watch Out! ELECTRIC
SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult sym-
bols and related instructions below for necessary actions to avoid the
hazards.

1-2.

Arc Welding Hazards

The symbols shown below are used throughout this manual
to call attention to and identify possible hazards. When you
see the symbol, watch out, and follow the related instructions
to avoid the hazard. The safety information given below is
only a summary of the more complete safety information
found in the Safety Standards listed in Section 1-5. Read and
follow all Safety Standards.

Only qualified persons should install, operate, maintain, and
repair this unit.

During operation, keep everybody, especially children, away.

ELECTRIC SHOCK can kill.

Touching live electrical parts can cause fatal shocks
or  severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic
wire welding, the wire, wire reel, drive roll housing,
and all metal parts touching the welding wire are
electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.

Do not touch live electrical parts.

Wear dry, hole-free insulating gloves and body protection.

Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.

Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.

Use AC output ONLY if required for the welding process.

If AC output is required, use remote output control if present on
unit.

Additional safety precautions are required when any of the follow-
ing electrically hazardous conditions are present: in damp
locations or while wearing wet clothing; on metal structures such
as floors, gratings, or scaffolds; when in cramped positions such
as sitting, kneeling, or lying; or when there is a high risk of unavoid-
able or accidental contact with the workpiece or ground. For these
conditions, use the following equipment in order presented: 1) a
semiautomatic DC constant voltage (wire) welder, 2) a DC manual
(stick) welder, or 3) an AC welder with reduced open-circuit volt-
age. In most situations, use of a DC, constant voltage wire welder
is recommended. And, do not work alone!

Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).

Properly install, ground, and operate this equipment according to
its Owner’s Manual and national, state, and local codes.

Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.

When making input connections, attach proper grounding conduc-
tor first − double-check connections.

Keep cords dry, free of oil and grease, and protected from hot metal
and sparks.

Frequently inspect input power cord for damage or bare wiring −
replace cord immediately if damaged − bare wiring can kill.

Turn off all equipment when not in use.

Do not use worn, damaged, undersized, or poorly spliced cables.

Do not drape cables over your body.

If earth grounding of the workpiece is required, ground it directly
with a separate cable.

Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.

Do not touch electrode holders connected to two welding ma-
chines at the same time since double open-circuit voltage will be
present.

Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.

Wear a safety harness if working above floor level.

Keep all panels and covers securely in place.

Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.

Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.

Do not connect more than one electrode or work cable to any
single weld output terminal. Disconnect cable for process not in
use.

SIGNIFICANT DC VOLTAGE exists in inverter weld-
ing power sources AFTER removal of input power.

Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.

HOT PARTS can burn.

Do not touch hot parts bare handed.

Allow cooling period before working on equip-
ment.

To handle hot parts, use proper tools and/or
wear heavy, insulated welding gloves and
clothing to prevent burns.

Summary of Contents for STR 400

Page 1: ...Processes STR 400 STR 500 OM 264 278A 2013 07 Description Arc Welding Power Source Stick SMAW Welding www MillerWelds com TIG GTAW Welding...

Page 2: ...ucts Please take time to read the Safety precautions They will help you protect yourself against potential hazards on the worksite We ve made installation and operation quick and easy With Miller you...

Page 3: ...s 8 3 4 Duty Cycle and Overheating 9 3 5 Volt Ampere Curves 10 3 6 Selecting A Location 11 3 7 Tipping 11 3 8 Weld Output Terminals and Selecting Cable Sizes 12 3 9 Remote Receptacle Information 13 3...

Page 4: ......

Page 5: ...ings or scaffolds when in cramped positions such as sitting kneeling or lying or when there is a high risk of unavoid able or accidental contact with the workpiece or ground For these conditions use t...

Page 6: ...tanks drums or pipes unless they are properly prepared according to AWS F4 1 and AWS A6 0 see Safety Standards Do not weld where the atmosphere may contain flammable dust gas or liquid vapors such as...

Page 7: ...PARTS can injure Keep away from moving parts such as fans Keep all doors panels covers and guards closed and securely in place Have only qualified persons remove doors panels covers or guards for mai...

Page 8: ...ntion During Welding Cutting and Other Hot Work NFPA Standard 51B from National Fire Protection Association Quincy MA 02269 phone 1 800 344 3555 website www nfpa org OSHA Occupational Safety and Healt...

Page 9: ...by insulating yourself from work and ground Safe3 2012 05 Disconnect input plug or power before working on machine Safe5 2012 05 Keep your head out of the fumes Safe6 2012 05 Use forced ventilation or...

Page 10: ...r local distributor for further information Safe37 2012 05 3 1 Safe49 2012 05 Move jumper links as shown on inside label to match input voltage at job site Include extra length in grounding conductor...

Page 11: ...nstant Current CC X Duty Cycle I1 Rated Supply Current I2 Rated Welding Current U0 Rated No Load Voltage Average U1 Rated Supply Voltage U2 Load voltage Line Connection Scratch Start TIG Adjust X Duty...

Page 12: ...Output 50 60 Hz Three Phase KVA KW Weight Dimensions mm L x W x H 230 V 400 V STR 400 400 A 36 Volts DC 35 Duty Cycle 20 400 A 82 V 57 5 A 33 A 22 8 19 8 Net 132 kg Ship 149 kg 1120 x 620 x 730 STR 50...

Page 13: ...s for unit to cool Reduce amperage or duty cycle before welding NOTICE Exceeding duty cycle can damage unit and void warranty 3 5 Minutes Welding 6 5 Minutes Resting Overheating 0 15 A or V OR Reduce...

Page 14: ...oltage and amperage output capa bilities of the unit 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 DC Amperes DC Volts STR 400 0 20 40 60 80 100 120140 160 180 200 220 240 260 280 300 320 340...

Page 15: ...ction 20 1 Lifting Eye 2 Lifting Forks Use lifting eye or lifting forks to move unit If using lifting forks extend forks beyond opposite side of unit 3 Line Disconnect Device Locate unit near correct...

Page 16: ...0 4 30 3 35 2 50 1 60 1 0 60 1 0 150 30 3 30 3 35 2 50 1 60 1 0 70 2 0 95 3 0 95 3 0 200 30 3 35 2 50 1 60 1 0 70 2 0 95 3 0 120 4 0 120 4 0 250 35 2 50 1 60 1 0 70 2 0 95 3 0 120 4 0 2x70 2 ea 2 0 2x...

Page 17: ...NTROL A Contact closure to B completes 24 volts AC con tactor control circuit B Contact closure to A completes 24 volts AC con tactor control circuit C Output to remote control 10 volts DC D Remote co...

Page 18: ...nected to the remote receptacle see Section 3 9 1 Remote Hand Control 2 Remote Foot Control 1 2 Ref 9561172120_1 A 3 12 Positioning Jumper Links Disconnect and lockout tag out input power before insta...

Page 19: ...e cord or cable is used minimum conductor size may increase See NEC Table 400 5 A for flexible cord and cable requirements Failure to follow these fuse and circuit breaker recommendations could create...

Page 20: ...OM 264 278 Page 16 3 14 Connecting 3 Phase Input Power input2 2012 05 956172120_1 A GND PE Earth Ground L1 2 1 L2 L3 3 3 4 5 6 7 Tools Needed...

Page 21: ...connect Device switch shown in the OFF position 3 Green Or Green Yellow Grounding Conductor 4 Disconnect Device Grounding Terminal 5 Input Conductors L1 L2 And L3 6 Disconnect Device Line Terminals Co...

Page 22: ...lection Switch Remote output is always On in TIG mode Hot Start function for Stick welding is disabled in TIG mode 5 TIG GTAW Welding Indicator Light 6 Power On Pilot Light 7 Welding Current Indicator...

Page 23: ...lectrode sticks to workpiece use a quick twist to free it 1 2 3 4 3 Scratch Start TIG Ref WM Marketing This starting method is not accept able for critical applications since small tungsten particles...

Page 24: ...e If any of these displays are shown check input power con nections If trouble continues contact a Factory Authorized Service Agent 1 2 3 AL1 AL2 AL3 5 3 Troubleshooting Trouble Remedy No weld output...

Page 25: ...se dry properly stored electrodes Low weld output with no control Check position of Amperage Control see Section 4 1 Limited output and low open circuit voltage Check incoming power for correct voltag...

Page 26: ...A complete Parts List is available at www MillerWelds com OM 264 278 Page 22 SECTION 6 ELECTRICAL DIAGRAMS Figure 6 1 Circuit Diagram For STR 400...

Page 27: ...A complete Parts List is available at www MillerWelds com OM 264 278 Page 23 956172121 A...

Page 28: ...A complete Parts List is available at www MillerWelds com OM 264 278 Page 24 Figure 6 2 Circuit Diagram For STR 500...

Page 29: ...A complete Parts List is available at www MillerWelds com OM 264 278 Page 25 956172123 A...

Page 30: ...up Retaining Wheel 2 2 8 156009127 Washer Round hooking For Handle 2 2 9 056020071 Knob for hose 25 mm dia 2 2 10 156002047 Handle 2 2 11 156018114 Nut Locking 2 2 12 156009128 Washer flat 10x30 6 6 1...

Page 31: ...70017 Link Primary Terminal 6 9 3 756069030 Board Primary Voltage Terminal 1 1 4 156005130 Support Voltage Change Board 1 1 5 L1 057098017 Choke 80x62x240 Al 1 5 L1 057098019 Choke 80x70x180 Al 1 6 T1...

Page 32: ...8 CB2 056067264 Breaker Circuit 10 A 1 1 29 656089026 Clamp Cable D30 1 1 30 S1 056067210 Switch 32 A 1 1 To maintain the factory original performance of your equipment use only Manufacturer s Suggest...

Page 33: ...Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...

Page 34: ...Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...

Page 35: ...ing Gear and Trailers Subarc Wire Drive Assemblies Water Coolant Systems USA Models Non Integrated Work Stations Weld Tables No Labor 5 6 Months Parts Batteries 6 90 Days Parts Accessory Kits Canvas C...

Page 36: ...y Zip Postal Code Please complete and retain with your personal records Owner s Record Always provide Model Name and Serial Style Number Contact a DISTRIBUTOR or SERVICE AGENCY near you Welding Suppli...

Reviews: