OM-271 435 Page 13
4-5.
Remote Receptacle Information
This unit automatically uses the remote control if connected to the remote receptacle.
A
B
C
D
E
REMOTE
Socket*
Socket Information
REMOTE
CONTROL
A
Contact closure to B completes 24 volts AC con-
tactor control circuit.
B
Contact closure to A completes 24 volts AC con-
tactor control circuit.
C
Output to remote control; +10 volts DC.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from re-
mote control.
* The remaining sockets are not used.
4-6.
Typical Connections For DCEP Stick (SMAW) Welding
956142993_1-A
1
Negative (−) Weld Terminal
2
Positive (+) Weld Terminal
3
Remote 14 Receptacle
For Direct Current Electrode
Positive (DCEP), connect elec-
trode holder cable to Positive (+)
terminal and work cable to Nega-
tive (−) terminal.
For Direct Current Electrode
Negative (DCEN), connect elec-
trode holder cable to Negative
(−) terminal, and work cable to
Positive (+) terminal.
Connect remote control if de-
sired. See Section 4-5.
This unit automatically uses
the remote control if con-
nected to the remote recep-
tacle (see Section 4-5).
1
2
3