OM-238 172 Page 17
4-8. Optional Meter Circuit Board Settings
805 228-A
Tools Needed:
Torx 25
1
Meter Circuit Board
2
DIP Switch S2
Set DIP switch S2 for type of
welding power source, and desired
wire feed speed display (see
illustration).
Reinstall wrapper.
1
2
X Indicates switch position does not affect
specified function.
.
Means switch must be in this position.
2
1
Digital Amperage Display
Hold Function ON
Hold Function OFF
Or
1
2
3
4
5
6
S2
1
2
3
4
5
6
1
2
3
4
5
6
Voltage Measurement
0-100V
Current Signal
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
(Step Voltage Power Source)
Signal Not Available
Wire Feed Speed Display
Inches/Minute
Current Signal Scale
0-10V (HD Output)
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
Or
0-10V
(Electronic Control P/Source)
Or
Or
Or
Signal Available
Meters/Minute
0-100 mV (Shunt)
Summary of Contents for ST-24 ce
Page 14: ...OM 238 172 Page 10...
Page 33: ...Notes...