![Miller S-74 MPa Plus Technical Manual Download Page 49](http://html1.mh-extra.com/html/miller/s-74-mpa-plus/s-74-mpa-plus_technical-manual_1796011049.webp)
TM-273245 Page 45
S-74 MPa Plus
9-12. Trigger Filter Board PC6 Test Point Values
a) Tolerance
−
±
10% unless specified
b) Triggered
−
means when gun trigger is
pressed
c) Reference RC5
−
2 for AC Circuit Common
Reference RC3
−
3 for DC Circuit Common
−
unless noted otherwise
d) Note
−
15 VDC measurements will be closer
to 14 V
PC6 Voltage Readings
Receptacle
Pin
Value
RC13
1
ISO SW OUT +15 volts DC
2
Push gun 15 volts DC when triggered
3
Not used
4
ISO SW OUT +15 volts DC
RC16
1
ISO SW OUT +15 volts DC
2
Push gun trigger 0 volts DC/15 volts DC when triggered
3
Not used
4
ISO SW OUT +15 volts DC
RC18
1
Gun motor tach 3.3 kHz to 42 kHz or 1.6 volts DC when running reference to RC8
−
15
2
Not used
3
Left trigger signal 0 volts DC/15 volts DC when triggered
4
Trigger signal A0 volts DC/15 volts DC when triggered
5
Not used
6
Left DSS Signal
7
Gun sense 2.7V for AlumaPro Plus reference to RC18
−
15
8
Gun command pot 0
−
5 volts DC reference to RC8
−
15
9
Gun command ref5 volts DC reference to RC8
−
15
10
Gun motor 0
−
24 volts DC reference to RC18
−
12
11
SW OUT +15 volts DC
12
Gun motor +24 volts DC
13
Jog 0 volts DC/15 volts DC when jogged
14
Purge 0 volts DC/15 volts DC when purged
15
Gun command common
16
RS485A
17
RS485B
18
ISO SW OUT +15 volts DC
RC19
1
Jog 0 volts DC/15 volts DC when jogged
2
Purge 0 volts DC/15 volts DC when purged
3
SW OUT +15 volts DC
Summary of Contents for S-74 MPa Plus