OM-220979 Page 18
General Terms:
Time
Indicates time values being set for timed functions (e.g. Preflow, Postflow which are only available in
the Arc On and Analog input or the Arc On and No Analog input modes).
TPS (Trigger Program Schedule)
TPS allows the operator to select weld programs by using the gun trigger. In TPS mode, momentarily
pressing the gun trigger allows the operator to cycle through preselected weld programs up to a total
of 8 programs.
Trigger Control
Selecting Trigger Control allows activating trigger functions such as DS, TH, 4T, TDS, and TPS.
Volts
Preset voltage in MIG mode at idle, actual voltage while welding, and 3 seconds hold value at end of
weld.
Wire Type
Selection of wire type by alloys and classification.
WFS
Term used to represent wire feed speed. In MIG mode, wire feed setting is independent of voltage
setting. In pulse, Accu-pulse, and RMD (optional) adjusting wire feed speed also increases power
level on wire electrode (one knob control).
4T
4T allows the operator to select between weld parameters and crater parameters using the gun
trigger. Crater time must be set for at least 0.2 seconds to make this function operational. If gun
trigger is released during welding, unit goes into trigger hold, then pressing and holding trigger again
causes unit to stay in crater until trigger is released and crater parameter times out.
6-2. Power Switch
1
Power Switch
803 694-A
1