Miller RFCS-RJ45 Owner'S Manual Download Page 2

OM-237 679 Page 2

3.

Operation

232 896

1

Material Switch

!

Do not use AC output in

damp areas, if movement is

confined, or if there is dan-

ger of falling. Use AC output

ONLY if required for the

welding process, and then

use a remote control.

!

Do not change position of

switch while welding or

while under load.

Use switch to select DC for steel,

stainless steel, and chrome-moly,

or AC for aluminum applications.
2

Material Thickness/Amperage

Control

Use control to select material thick-

ness and corresponding amper-

age.

When Material switch is in the DC

position, use the blue scale to se-

lect the appropriate material thick-

ness and corresponding amperage

from the white scale. When Material

switch is in the AC position, use the

gray scale to select the appropriate

material thickness and correspond-

ing amperage from the white scale.

Set maximum desired amperage.

The maximum amperage available

when using the foot control will be

the value the Amperage control dial

is set at.
3

Foot Control

Press pedal lightly to turn weld

output and gas flow on. Press pedal

further to increase weld output.

Raise pedal to reduce amperage,

crater-out, and turn off weld output

and gas flow.

3

2

1

4.

Troubleshooting

Trouble

Remedy

No weld output

Be sure foot control cord is plugged into matching receptacles on welding power source and back of

foot control.

Not enough weld amperage

Set weld amperage to highest desired value on welding power source Material Thickness/Amperage

control. Amperage available with foot control is 10 amps to max value set on Thickness/Amperage

control.

5.

Parts

Description

Part

No.

Quantity

300 432

RFCS

RJ45 (FOOT CONTROL) 

1

. . . 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

237 678

FOOT CONTROL, RFCS

RJ45  

1

. . . 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

237 676

CABLE CONNECTING, W/CONNECTORS 14

1/2 FT 

1

. . . 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 