OM-246 466 Page 20
Ref. 803 676-A
2
3
3-12. Rear Panel Receptacles And Supplementary Protectors
1
6
4
5
1
115 V 10 A AC Receptacle RC2
Receptacle supplies 60 Hz
single-phase power. Maximum output
from RC2 is limited by supplementary
protector CB1 to 10 amps.
2
Supplementary Protector CB1
3
Supplementary Protector CB2
CB1 protects 115 volt receptacle RC2
from overload. If CB1 opens, RC2 does
not work.
CB2 is rated at 15 amperes and protects
the wire feeder from overload. If CB2
opens, the wire feeder does not work.
.
Press button to reset breaker. If
breaker continue to open, contact a
Factory Authorized Service Agent.
4
Wire Feed/Gas Receptacle RC8
Use receptacle to connect PipePro
interconnect cable to power source
(see Sections 3-14 and 8 for additional
information).
5
Peripheral Receptacle RC25
Receptacle provides connection to the
water flow switch (see Section 3-13).
6
Interface Receptacle RC72
Use receptacle to connect PipePro
interconnect cable (see Section 8 for
additional information).