OM-246 022 Page 11
3-7.Connecting Receiver To Remote 14 Receptacle
Ref. 804 746 / 805 483-A
!
Unexpected weld output can
cause electrical shock. Wire-
less remote control can turn
weld output on from distant
locations. Disconnect re-
ceiver from remote 14 re-
ceptacle and remove battery
from remote control before
servicing equipment.
Turn Off welding power source.
1
Receiver
2
Nut (Yellow)
Insert receiver into matching
14-socket receptacle on welding
power source. Tighten yellow nut
clockwise.
Turn welding power source on.
3
LED (Green)
LED Diagnostics:
Constant on LED = Power on
Blinking LED = Communicating
with transmitter
Slow blinking LED = Address learn-
ing mode
NOTICE
−
To remove receiver, ro-
tate yellow nut counterclockwise.
1
3
2
3-8.Remote Foot Control Operation
!
Unexpected weld output can
cause electrical shock. Wire-
less remote control can turn
weld output on from distant
locations. Disconnect receiver
from remote 14 receptacle and
remove battery from remote
control before servicing equip-
ment.
1
Remote Foot Control
Use control to turn on output contact-
or and control amperage remotely.
.
This control does not override
welding power source panel set-
tings.
Welding power source panel settings:
Place output contactor control in re-
mote position.
Place amperage control in Remote
position.
1
805 481