A complete Parts List is available at www.MillerWelds.com
OM-253392 Page 11
SECTION 4
−
SPECIFICATIONS
4-1. Serial Number And Rating Label Location
The serial number and rating information for this product is located on the side. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.
4-2. Unit Specifications For MIG (GMAW)
.
Do not use information in unit specifications table to determine electrical service requirements. See Sections 5-10, 5-12, and 5-13 for information
on connecting input power.
.
This equipment will deliver rated output at an ambient air temperature up to 104
5
F (40
5
C).
Input
Voltage
Rated Welding
Output
Amperage
Range
Maximum Open-
Circuit Voltage
DC
Amperes Input at Rated
Load Output, 50/60 Hz,
Single-Phase
120 VAC
110 A @ 19.5 Volts DC,
20% Duty Cycle
75 A @ 17.75 Volts DC,
100% Duty Cycle
*
30
−
140
90
22.4
14.6
*
Wire Type
And Diameter
Solid/Stainless
Flux Cored
Wire Feed Speed Range
.023 - .035 in.
(0.6 - 0.8 mm)
.030 - .035 in.
(0.8 - 0.9 mm)
70
−
425 IPM (1.75
−
10.8 m/min)
230 VAC
150 A @ 21.5 Volts DC,
20% Duty Cycle
120 A @ 20 Volts DC,
100% Duty Cycle*
30
−
200
90
17.5
13.1*
Wire Type
And Diameter
Solid/Stainless
Flux Cored
Wire Feed Speed Range
.023
−
.035 in.
(0.6
−
0.9 mm)
.030
−
.045 in.
(0.8
−
1.2 mm)
70
−
425 IPM (1.75
−
10.8 m/min)
* CSA Rating
4-3. Unit Specifications For TIG (GTAW)
.
Do not use information in unit specifications table to determine electrical service requirements. See Sections 5-10, 5-12, and 5-13 for information
on connecting input power.
.
This equipment will deliver rated output at an ambient air temperature up to 104
5
F (40
5
C).
Input
Voltage
Rated Welding
Output
Amperage
Range
Maximum Open-
Circuit Voltage
DC
Amperes Input at Rated
Load Output, 50/60 Hz,
Single-Phase
120 VAC
150 A @ 16 Volts DC,
30% Duty Cycle
70 A @ 13 Volts DC,
100% Duty Cycle
*
5
−
150
90
27.0
10.5
*
230 VAC
150 A @ 16 Volts DC,
30% Duty Cycle
100 A @ 14 Volts DC,
100% Duty Cycle*
5
−
150
90
13.8
15.9*
* CSA Rating
Summary of Contents for Multimatic 200
Page 45: ...OM 253392 Page 41 Notes ...
Page 46: ...OM 253392 Page 42 SECTION 8 ELECTRICAL DIAGRAM Figure 8 1 Circuit Diagram ...
Page 47: ...OM 253392 Page 43 264 018 A ...