A complete Parts List is available at www.MillerWelds.com
OM-253392 Page 32
6-6. Calibrating Spoolmate 100 Or Spoolmate 150 (Menu 3 Of 10)
1
Material Thickness Plus (+)
Button
2
Left Adjustment Knob
3
Right Adjustment Knob
.
Spoolmate 100 and 150 drive
motors are unique to this welding
power source. Motor calibration
is necessary any time a different
Spoolmate is connected to the
Multimatic 200.
Connect Spoolmate to unit. Cut wire
flush at nozzle.
Follow instructions in Section 6-3 to
enter the setup menu.
Press Material Thickness Plus (+)
button twice after entering setup to
enter the Spoolmate Calibration
menu.
To perform a Spoolmate calibration
24 in. runout test at 100 ipm, turn left
Adjustment knob and verify that a (
n
)
check mark appears next to 100 IPM.
Be sure that wire is cut flush at nozzle,
then trigger the Spoolmate.
Spoolmate will feed approximately 24
in. of wire through gun.
Cut wire flush at nozzle and measure
run-out.
If wire is not 24 inches long, use left
Adjustment knob to increase or de-
crease the length of the run-out and
repeat the test.
To perform a Spoolmate calibration
24 in. runout test at 300 ipm, turn right
Adjustment knob and verify that a (
n
)
check mark appears next to 300 IPM.
Be sure that wire is cut flush at nozzle,
then trigger the Spoolmate.
Spoolmate will feed approximately 24
in. of wire through gun.
Cut wire flush at nozzle and measure
run-out.
If wire is not 24 inches long, use right
Adjustment knob to increase or de-
crease the length of the run-out and
repeat the test.
Cycle through menu items using the
Material Thickness Plus (+) button or
cycle unit power to save settings and
exit menu.
.
Cycle unit power before welding
to complete initialization process.
Ref. 249 632-F
Tools Needed:
2
3
1
Summary of Contents for Multimatic 200
Page 45: ...OM 253392 Page 41 Notes ...
Page 46: ...OM 253392 Page 42 SECTION 8 ELECTRICAL DIAGRAM Figure 8 1 Circuit Diagram ...
Page 47: ...OM 253392 Page 43 264 018 A ...
Page 66: ...Notes ...