OM-196 596 Page 17
4-4.
Optional 115 Volt AC Duplex Receptacle And Circuit Breakers
ST-801 245-A
1
115 V 7 A AC Receptacle
Power is shared between duplex
receptacle and Remote 14 recep-
tacle (see Section 4-3).
2
Circuit Breaker CB1
CB1 protects duplex receptacle
and 115 volt ac portion of Remote
14 receptacle from overload.
3
Circuit Breaker CB2
CB2 protects 24 volt ac portion of
Remote 14 receptacle from
overload.
Press button to reset breaker.
2
3
1
4-5.
Electrical Service Guide
Actual input voltage should not exceed
±
10% of indicated required input voltage. If
actual input voltage is outside of this range, output may not be available.
NOTE
Input Voltage
400
Input Amperes At Rated Output
17.0
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
30
Reference: 1996 National Electrical Code (NEC).
S-0092J