OM-222 Page 28
SECTION 5
−
OPERATION
5-1. Controls (Non CE Models)
1
Polarity Selector Switch (Optional On 50
Hz Models)
To change polarity on models not equipped
with a Polarity Selector switch, reverse work
and electrode cables at the weld output termi-
nals (see Section 4-11).
!
Turn Off Power before reversing
cables.
2
Arc Force (Dig) Control
Control increases SMAW short-circuit amper-
age which allows the operator to use a very
short arc length without sticking the electrode.
Set control at 0 for normal welding amperage.
Turn clockwise to increase short-circuit
amperage.
3
Hot Start Switch
Turn switch On for SMAW and Off for GTAW
welding.
4
Amperage Adjustment Control
5
Digital Meters (Optional)
6
Power Switch With Indicator Light
7
High Temperature Shutdown Light
8
Remote Amperage Control Switch
For front panel control, place switch in Panel
position. For remote control, place switch in
Remote position, and connect remote device
(see Section 4-14).
9
Output Switch (Contactor)
For front panel control of output, place switch
in Panel position. For remote control of output,
place switch in Remote position, and connect
remote device (see Section 4-14).
!
Turn Off power before connecting re-
mote device.
165 596-G
300 Amp Model Shown
1
2
8
9
4
6
7
3
5
Summary of Contents for Gold Star 302
Page 14: ...OM 222 Page 10...
Page 18: ...TM 216 869 Page 14 Dynasty 350 700 Maxstar 350 700 Notes...
Page 36: ...OM 222 Page 32 SECTION 7 ELECTRICAL DIAGRAM Figure 7 1 Circuit Diagram...
Page 37: ...OM 222 Page 33 218 518 C...
Page 45: ...Notes...
Page 46: ...TM 216 869 Page 42 Dynasty 350 700 Maxstar 350 700 Notes...