OM-254063 Page12
SECTION 4 − SPECIFICATIONS
4-1.
Serial Number And Stock Number Location
The serial number and rating information for this product is located on the rear panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on back cover of this manual.
4-2.
Unit Specifications
Type of Input
Power
Welding Power
Source Type
Wire Feed Speed
Range
Wire Diameter
Range
Welding Circuit
Rating
Ship Weight
24 Volts AC
Single-Phase
10 Amperes
50/60 Hertz
Constant Voltage (CV)
DC With 14-Pin And
Contactor Control
Standard: 50 To 780 ipm
(1.3 To 19.8 mpm)
.023 To 1/8 in. (0.6
To 3.2 mm)
Max Spool Weight:
60 lb (27 kg)
100 Volts,
600 Amperes, 100%
Duty Cycle
8 ft (2.4 m):
400 lb (181 kg)
12 ft (3.7 m):
410 lb (186 kg)
16 ft (4.9 m):
470 lb (213 kg)
8 ft (2.4 m) Boom
12 ft (3.7 m) Boom
16 ft (4.9 m) Boom
Maximum Height With 4 ft
(1.2 m) Post
13 ft (3.9 m)
17 ft (5.2 m)
21 ft (6.4 m)
Vertical Lift Of Boom
Horizontal to 60
°
Above Horizontal
Horizontal to 60
°
Above Horizontal
Horizontal to 60
°
Above Horizontal
4-3.
Environmental Specifications
A. IP Rating
IP Rating
IP2X
This equipment is designed for indoor use and is not intended to be used or stored outside.
IP2X 2014−06
B. Temperature Specifications
Operating Temperature Range
Storage/Transportation Temperature Range
14 to 104
°
F (−10 to 40
°
C)
−4 to 131
°
F (−20 to 55
°
C)
Temp1_016- 08
Notes
Summary of Contents for D-74 MPa Plus