Complete Parts List is available at www.MillerWelds.com
OM-258413 Page 35
7-2. GFCI Receptacle Information, Resetting, And Testing
!
Use GFCI protection when operat-
ing auxiliary equipment. If unit does
not have GFCI receptacles, use
GFCI-protected extension cord. Do
not use GFCI receptacle to power
life support equipment.
!
Unplug power cord before attempt-
ing to service accessories or tools.
1
120 V 20 A AC GFCI Receptacle
2
GFCI Receptacle Test Button
3
GFCI Receptacle Reset Button
4
Red GFCI Indicator Light (LED)
5
Green GFCI Indicator Light (LED)
.
Red and Green indicator lights may be
combined in a single LED.
GFCI Receptacles
GFCI receptacles protect the user from
electric shock if a ground fault occurs in
equipment connected to the receptacle. A
ground fault occurs when electrical current
takes the shortest path to ground (which
could be through a person) rather than fol-
low its intended safe path.
If a ground fault is detected, the GFCI Reset
button pops out, and the circuit opens to
disconnect power to the faulty equipment.
A GFCI receptacle does not protect against
circuit overloads, short circuits, or shocks
not related to ground faults. Reset and test
GFCI receptacle according to the following
procedures.
A solid green LED indicates power to the
GFCI. A solid red LED indicates that the
GFCI has been tripped.
Resetting/Testing GFCI Receptacle
!
Test GFCI monthly.
!
If Red LED blinks, stop using GFCI
receptacle and have a Factory Au-
thorized Service Agent replace it.
!
Extension cords with bad insulation
or of extended length can allow
enough leakage current to trip the
GFCI circuit. Reset and test as
follows.
Resetting GFCI Receptacles
If a GFCI fault occurs, stop engine and dis-
connect equipment from GFCI receptacle.
Check for damaged or wet tools, cords,
plugs, etc. connected to the receptacle.
Start engine, place engine control switch in
RUN position, and press GFCI Reset but-
ton. Reconnect equipment to GFCI recep-
tacle. If GFCI Reset button pops out again,
check the equipment and repair or replace
if faulty.
Testing GFCI Receptacles
Start engine and place engine control
switch in Run position. Press the GFCI Test
button. The GFCI Reset button should pop
out.
Press the GFCI Reset button.
Have a Factory Authorized Service
Agent replace GFCI if any of the follow-
ing occur:
GFCI does not trip when tested
Red LED blinks
GFCI does not reset.
1
2
3
4
RotGFCI1 2018-12
5
.
Orientation of receptacle may be different in other applications.
.
Alternate location for red
and green indicator LEDs.