OM-271 838 Page 34
!
Use GFCI protection when operating
auxiliary equipment. If unit does not
have GFCI receptacles, use GFCI-
protected extension cord. Do not
use GFCI receptacle to power life
support equipment.
!
Unplug power cord before attempt-
ing to service accessories or tools.
1
120 V 20 A AC GFCI Receptacle
2
GFCI Receptacle Test Button
3
GFCI Receptacle Reset Button
4
GFCI Indicator Light (LED)
GFCI Receptacles
GFCI receptacles protect the user from
electric shock if a ground fault occurs in
equipment connected to the receptacle. A
ground fault occurs when electrical current
takes the shortest path to ground (which
could be through a person) rather than fol-
low its intended safe path.
If a ground fault is detected, the GFCI Reset
button pops out, and the circuit opens to dis-
connect power to the faulty equipment. A
GFCI receptacle does not protect against
circuit overloads, short circuits, or shocks
not related to ground faults. Reset and test
GFCI receptacle according to the following
procedures.
Resetting/Testing GFCI Receptacle
!
Test GFCI monthly. See Testing
GFCI Receptacle.
!
Do not test or reset GFCI receptacles
at idle speed/
low voltage
or the GFCI
will be damaged and not provide
protection from electric shock
caused by a ground fault.
!
If LED blinks, stop using GFCI re-
ceptacle and have it replaced by a
Factory Authorized Service Agent.
!
Extension cords with bad insulation
or of extended length can allow
enough leakage current to trip the
GFCI circuit. Reset and test as fol-
lows.
Resetting GFCI Receptacles
If a GFCI fault occurs, stop engine and dis-
connect equipment from GFCI receptacle.
Check for damaged or wet tools, cords,
plugs, etc. connected to the receptacle.
Start engine and operate at Run (weld/
power) speed.
Press GFCI Reset button.
Reconnect equipment to GFCI receptacle.
If GFCI Reset button pops out again, check
the equipment and repair or replace if faulty.
Testing GFCI Receptacles
GFCI testing must be done with engine
running at Run (weld/power) speed.
Start engine and operate at Run (weld/
power) speed.
Press the GFCI Test button. The GFCI Re-
set button should pop out.
Press the GFCI Reset button.
Have GFCI replaced by a Factory Au-
thorized Service Agent if any of the fol-
lowing occur:
GFCI does not trip when tested
LED blinks
GFCI does not reset.
1
2
3
4
RotGFCI1 2014
−
09
!
Test and reset GFCI only at Run speed.
7-2. GFCI Receptacle Information, Resetting And Testing