OM-220 389 Page 18
Ref. 803 417-A
1
115 V 10 A AC Receptacle RC2
Receptacle supplies 60 Hz
single-phase power. Maximum output
from RC2 is limited by supplementary
protector CB1 to 10 amps.
2
Supplementary Protector CB1
3
Supplementary Protector CB2
CB1 protects 115 volt receptacle RC2
from overload. If CB1 opens, RC2 does
not work.
CB2 protects the wirefeed motor from
overload. If CB2 opens, the wirefeeder
does not work.
.
Press button to reset breaker. If
breaker continue to open, contact a
Factory Authorized Service Agent.
4
Network Wire Feeder Receptacle
RC1
Use receptacle to connect network
feeder cable to power source (see
Section 5-7).
2
3
5-8. Rear Panel Receptacles And Supplementary Protectors
1
4
5-9. Network Wire Feeder Receptacle Functions
9
Pin*
Pin Information
Ref. 803 417-A
A
B
I
C
H
D
G
E
F
A
Not used.
B
Shield.
C
Volt sense.
D
Can low.
E
Can high.
F
+24 volts DC common.
G
+ 24 volts DC
H
Motor voltage
−
40 volts
I
Motor v40 volts
*The remaining pins are not used.