12-2. Voltmeter/Ammeter Display Messages
.
All directions are in reference to the
front of the unit. All circuitry referred to
is located inside the unit.
1
[RELE] [ASE] / [TRIG] [GER]
Remote 14 receptacle contactor control
(Pins A
−
B) must be opened before pro-
ceeding.
2
[UN S] [HORT] / [OUTP] [UT]
Short on weld output connections must be
removed before proceeding. See Section
12-3 if display shows after weld output con-
nections have been verified as not having
a short.
3
[OVER] [TEMP]
Over temperature condition has occurred.
Error will clear after temperatures reach ac-
ceptable levels.
4
Latching Errors:
When one of the following errors occurs,
the Standby LED flashes. To clear error,
press Standby button or turn off power. See
Section 12-3 if error does not clear or hap-
pens frequently.
[CHEK] [INPT] Check Input
High or low voltage has been sensed. Have
a qualified person check input voltage.
[WELD] [CABL] Weld Cable
An error related to the weld cables has been
sensed. Straighten out or shorten weld
cables. If carbon arc gouging, adjust DIG
setting to CARBon ARC. See Section 6-4
(Dynasty), 7-2 (Dynasty DX), 9-3 (Maxstar)
or 10-2 (Maxstar DX).
[SEE] [O.M.] See Owner’s Manual: See
Section 12-3.
[COOL] [PWR] Cooler Power
An error related to the CoolMate 1.3 Power
has occurred. When error will not clear or
occurs frequently, cooler can be plugged in-
to a nearby 115 volt AC receptacle, or ma-
chine can be used without the Cooler
Power, turn Cooler Power off (see Section
5
[NOT] [VALD]
Message is displayed when attempting an
incompatible setup; i.e., pressing AC
Waveshape while in DC.
6
[LOCK] [LEV1], 2, 3, 4
Is displayed when attempting adjustments
that are incompatible with the active selec-
ted lock level.
7
[SOFT] [WARE] [NOT] [VALD]
A software compatibility error has been de-
tected. A software update is required (see
Section 5-12 Software Updates). See Sec-
tion 12-3 if display shows after a software
update is performed.
1
2
3
4
6
5
RELE
ASE
TRIG
GER
UN S
HORT
OUTP
UT
OVER TEMP
Release Trigger
Un Short Output
Over Temperature Error
Latching Errors:
CHEK
INPT
WELD CABL
SEE
O.M.
}
Latching Errors:
NOT
VALD
Not Valid
LOCK
LEV1
Lock Level
COOL
PWR
SOFT
WARE
NOT
VALD
Software Not Valid