SECTION 11
−
ADVANCED MENU FUNCTIONS
[ARC] [T/CY] Arc Timer:
Monitors hours, minutes, and cycles of valid arc
on. To view, rotate amperage adjustment control. To reset, rotate amper-
age adjustment control until [RESET] [YES] is displayed. Press Menu
button to display [RESET] [Done]. Displays turn to [000] [000].
11-1. Accessing Tech Menu For Dynasty/Maxstar 210 Models
1
Menu Button
Press and hold Menu button for ap-
proximately four seconds to scroll
past User Menu to Tech Menu. Use
Menu button to cycle through
parameters that can be set.
2
Parameter Display
3
Setting Display
4
Amperage Adjustment Control
Rotate amperage adjustment con-
trol to adjust parameter setting.
.
Dynasty 210 shown, Maxstar
menus are the same. Menu
order may vary.
To exit tech menu, press and hold
menu button approximately one
second, or turn power off.
.
Settings in the Tech Menu are
global, meaning they may
pertain to all or some of the
process.
1
MENU
2
3
4
TECH
OFF
SLEP
T/CY
ARC
NORM
OCV
OFF
STUC
RSET
MACH
WARE
SOFT
[SLEP] Sleep Timer:
Turns power off after the machine exceeds the pro-
grammed idle time without operation. Press the Standby button to turn power
on. To set or change time, rotate amperage adjustment control to desired time.
Timer range: 1, 5, 10, 20, 30, 45 minutes or one hour.
[STUC] Stick Stuck:
Detects if the electrode is stuck or shorted to the
workpiece. Turns weld output off to aid in freeing the electrode. To turn on,
rotate amperage adjustment control. Not recommended for air carbon arc
or large diameter electrodes.
[MACH] [RESET] Machine Reset:
Resets all machine values back to
factory defaults. To reset, turn amperage adjustment control to [RESET]
[YES]. Then press Menu button. [RESET] [DONE] will be displayed
when the reset is complete and factory defaults have been restored.
[OCV] Open Circuit Voltage:
Allows user to select between Normal
(NORM) and Low open circuit voltage. Low reduces open circuit voltage
to between 8 and 15 volts. To select, turn amperage adjustment control.
[SOFT] [WARE] Software Number:
Software number and revision will
be displayed.
LOG
ERR
[ERR] [LOG] Error Log:
Use to view last eight logged error events. Each
event may list multiple Error Codes. See Section 12-3.
NUM
SERL
[SERL] [NUM] Serial Number:
If serial number displayed does not
match serial number of machine, see Section 12-3.
AUTO
COOL
[COOL] Cooler Power
(Optional)
:
Selects
between [OFF], [ON] (Non
CE models Only), and [AUTO]. [OFF] disables the power supply to the
receptacle. [ON] enables the power supply to the receptacle. [AUTO]
provides power to the receptacle when the TIG process is active.
247222-D
Summary of Contents for 907684001
Page 6: ......
Page 46: ...A complete Parts List is available at www MillerWelds com OM 270536 Page 38 Notes...
Page 79: ...OM 270536 Page 71 Figure 14 2 Circuit Diagram For Maxstar 210 255981 H...
Page 88: ...Notes...
Page 89: ...Notes...
Page 90: ...Notes...