The
temperature screen
is the main screen for all heating processes and is the
default screen
that appears when the
unit is turned on.
If a preconfigured heating program has been loaded from the ArcReach Heater data app, the Weld ID is shown at the
top of the screen. The current time, date and recording timer also display at the top. The time format can either be
12-hour or 24-hour.
You can change the time format on the User Settings screen in the System Menu.
A
recording indicator flashes
while data is being recorded. The main section shows readings for all connected thermocouples
(TCs). If a control TC is not sending a reading, the background of that TC turns red.
The information in the right panel depends on the current heating process — preheat or bakeout.
By default, preheat information is displayed, including a target temperature. You can adjust the target temperature using
the up/down arrow buttons. If a loaded preheat program includes range limits, the range displays below the target
temperature.
Quick Program Guide
ArcReach
®
Heater
10
NOTE:
TC 1
Manage Control TCs
Program
Save Data
SET TARGET
14:24 1/23/19
00:00:00
PREHEAT
TC 5
?
CONTROL
CONTROL
CONTROL
CONTROL
TC 3
NO SIGNAL
TC 2
NO SIGNAL
TC 6C
TC 4C
70
69
70
70
200º