![Miller 028042108 Owner'S Manual Download Page 9](http://html1.mh-extra.com/html/miller/028042108/028042108_owners-manual_1796026009.webp)
OM-270223 Page 5
SECTION 3
−
SPECIFICATIONS
3-1. Serial Number And Rating Label Location
The serial number and rating information for this product is located on the back panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on cover of this manual.
3-2. Specifications*
Do not use information in unit specifications table to determine electrical service requirements. See Sections 4-3 for information on connecting
input power.
This equipment will deliver rated output at an ambient air temperature up to 104
F ( 40
C).
Model
Coolant Tank
Capacity
Maximum Cooling
Capacity
Input Power
Dimensions
Weight
Coolmate 1.3 CE
5 L
1470 Watts
(5020 BTU/hr)
1.0 L/min
(1.1 qt/min)
Single Phase
115 VAC
50/60 Hz
2.5 Amperes
Length: 620 mm
Height: 320 mm
Width: 227 mm
20 kg
*IEC Cooling Capacity States That The Water Inlet Temperature Can Not Exceed 40
°
C Above Ambient Temperature At A 1l/ Min Flow Rate.
**Plug Is Customer Supplied.
Recirculating Coolant System For Water-Cooled GTAW Torches And GMAW Guns.
Use With Guns/Torches Rated Up To 280 Amperes
3-3. Coolant Specifications
Do not use conductive coolant.
Application
Coolant
GTAW Or Where High Frequency Current Is Used
Coolant 050024004
Low Conductivity Coolant 043810*
Distilled Or Deionized Water Okay Above
32
°
F (0
°
C)
GMAW Or Where High Frequency Current Is Not Used
Coolant 050024004
Low Conductivity Coolant 043810*
Aluminum Protecting Coolant 043809*
Distilled Or Deionized Water Okay Above
32
°
F (0
°
C)
Where Coolant Contacts Aluminum Parts
Aluminum Protecting Coolant 043809*
*Coolants 043810 and 043809 protect to -37
°
F (-38
°
C) and resist algae growth.
NOTICE
−
Use of any coolant other than those listed in the table voids the warranty on any parts that come in contact with the coolant (pump, radiator,
etc.).
3-4. Environmental Specifications
A. IP Rating
IP Rating
IP23
This equipment is designed for outdoor use.
IP23 2017
−
02
B. Information On Electromagnetic Compatibility (EMC)
!
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low
−
voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations, due to con-
ducted as well as radiated disturbances.
This equipment complies with IEC 61000-3-11 and IEC 61000-3-12.
ce-emc 4 2014-07
C. Temperature Specifications
Operating Temperature Range
Storage/Transportation Temperature Range
−
10 to 40
°
C (14 to 104
°
F)
20 to 25
°
C (68 to 77
°
F)
Temp1_016- 08
The correction factor on the cooling power at an ambient temperature of 104
F (40
C) is 0.625.