4
Sequencer**
Module
Pulser*
Module
1
8
7
9
10
11
12
13
14
15
16
17
18
2
3
4
5
6
19
20
Common Bottom Panel
Control Panels
1.
Voltmeter Display
2.
Start Mode Control
(Lift-Arc, HF Start, HF Continuous)
3.
Output Control
4.
Amperage Control (Panel/Remote)
5.
Process Control (Stick/TIG)
6.
Balance/Dig Control (0 – 10)
7.
Postflow Time Control (0 – 50 sec)
8.
Ammeter Display
9.
Pulser Control*
10.
Background Amps Control (0 – 100%)*
11.
Pulse-Per-Second Control (0.25 – 10 Hz)*
12.
Peak Time Control (5 – 95%)*
13.
Spot Time Control (0 – 5 sec)*
14.
Final Slope Control (0 – 25 sec)*
15.
Initial Time Control (0 – 15 sec)*
16.
Final Amperage Control (0 – 100%)*
17.
Initial Amperage Control (3 – 310/400 A)*
18.
Amperage Adjustment Control (3 – 310/400 A)
19.
Power Switch (On/Off)
20.
Output Selector Switch (AC/DC-/DC+)
*Optional Pulser for 250 DX