TM-353 Page 27
Syncrowave 250
SC-188 161
Test Equipment Needed:
V24
V22
V21
R3
R2
V20
A A
A
A
R1
V25
Resistance Values
a)
Tolerance –
±
10% unless specified
b)
Turn Off unit and disconnect input
power before checking resistance
R1
All values for T1, Z1, and T3 are less
than 1 ohm
R2
5.3 ohms
R3
6.1 K ohms
Voltage Readings
a)
Tolerance –
±
10% unless
specified
b)
Reference
– to circuit
common (lead 42) unless
noted
c)
Wiring Diagram – see
Section 10
V1
230 volts ac
V2
77 volts ac
V3
82.5 volts ac
V4
57 volts ac
V5, V6
115 volts ac
V7
24 volts ac
V8, V9
18 volts ac
V10
10 volts ac
V11
80 volts dc
V12. V13, V14
115 volts ac
V15, V16, V17
24 volts ac
V18
115 volts ac with S2
in Start or Con-
tinuous
V19
0 to +10 volts dc
with contactor on
V20, V21
24 volts dc
V22
0-80 volts dc (rec-
tified arc voltage)
V23
maximum 80 volts
ac/dc
V24
24 volts dc
V25
16.5 millivolts dc
per 1 ampere of
weld output
CR1 energizes
when open-circuit voltage
is present; denergizes
when an
arc is struck
See Figure 10-1 for
HD1 location
No calibration available
for voltmeter V1
R1
V23, B,
C, D, E
See Section 6-3
for waveforms
B, C, D, E
See also
Sections 6-4 and 6-5
for PC1 data
CR5 energizes when
contactor is on
See Section 6-8
for ammeter A1
calibration
V19
V18
See Section 6-3
for waveform A
Summary of Contents for SYNCROWAVE 250