background image

OM-1597 Page 1

SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING

som _nd_4/98

1-1.

Symbol Usage

Means Warning! Watch Out! There are possible hazards
with this procedure! The possible hazards are shown in
the adjoining symbols.

Y

Marks a special safety message.

.

Means “Note”; not safety related.

This group of symbols means Warning! Watch Out! possible
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.
Consult symbols and related instructions below for necessary actions
to avoid the hazards.

1-2.

Arc Welding Hazards

Y

The symbols shown below are used throughout this manual to
call attention to and identify possible hazards. When you see
the symbol, watch out, and follow the related instructions to
avoid the hazard. The safety information given below is only
a summary of the more complete safety information found in
the Safety Standards listed in Section 1-4. Read and follow all
Safety Standards.

Y

Only qualified persons should install, operate, maintain, and
repair this unit.

Y

During operation, keep everybody, especially children, away.

ELECTRIC SHOCK can kill.

Touching live electrical parts can cause fatal shocks
or  severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also

live when power is on. In semiautomatic or automatic wire welding, the
wire, wire reel, drive roll housing, and all metal parts touching the
welding wire are electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.

D

Do not touch live electrical parts.

D

Wear dry, hole-free insulating gloves and body protection.

D

Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.

D

Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.

D

Use AC output ONLY if required for the welding process.

D

If AC output is required, use remote output control if present on
unit.

D

Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).

D

Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.

D

Always verify the supply ground – check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.

D

When making input connections, attach proper grounding conduc-
tor first – double-check connections.

D

Frequently inspect input power cord for damage or bare wiring –
replace cord immediately if damaged – bare wiring can kill.

D

Turn off all equipment when not in use.

D

Do not use worn, damaged, undersized, or poorly spliced cables.

D

Do not drape cables over your body.

D

If earth grounding of the workpiece is required, ground it directly
with a separate cable.

D

Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.

D

Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.

D

Wear a safety harness if working above floor level.

D

Keep all panels and covers securely in place.

D

Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.

D

Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.

D

Do not connect more than one electrode or work cable to any
single weld output terminal.

SIGNIFICANT DC VOLTAGE exists after removal of
input power on inverters.

D

Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.

Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.

FUMES AND GASES can be hazardous.

D

Keep your head out of the fumes. Do not breathe the fumes.

D

If inside, ventilate the area and/or use exhaust at the arc to remove
welding fumes and gases.

D

If ventilation is poor, use an approved air-supplied respirator.

D

Read the Material Safety Data Sheets (MSDSs) and the
manufacturer’s instructions for metals, consumables, coatings,
cleaners, and degreasers.

D

Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watch-
person nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breath-
ing air is safe.

D

Do not weld in locations near degreasing, cleaning, or spraying op-
erations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.

D

Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and if necessary, while wearing an
air-supplied respirator. The coatings and any metals containing
these elements can give off toxic fumes if welded.

Summary of Contents for SWLL-115

Page 1: ...R 115 SWSL 115 And SWLR 115E Processes Description OM 1597 192 710 November 1998 Automatic Welding Heavy Duty Wire Feeder For Automated Welding Applications Motor Drive Assemblies Visit our website at...

Page 2: ...alue established in 1929 This Owner s Manual is designed to help you get the most out of your Miller products Please take time to read the Safety precautions They will help you protect yourself agains...

Page 3: ...l installation le fonctionnement et la maintenance 7 1 4 Principales normes de s curit 8 1 5 Information sur les champs lectromagn tiques 8 SECTION 2 INSTALLATION 9 2 1 Specifications 9 2 2 Descriptio...

Page 4: ......

Page 5: ...that cord plug is connected to a properly grounded receptacle outlet D When making input connections attach proper grounding conduc tor first double check connections D Frequently inspect input power...

Page 6: ...lding wire at contact tip when not in use D Wear oil free protective garments such as leather gloves heavy shirt cuffless trousers high shoes and a cap D Remove any combustibles such as a butane light...

Page 7: ...aintained D Keep high frequency source doors and panels tightly shut keep spark gaps at correct setting and use grounding and shielding to minimize the possibility of interference ARC WELDING can caus...

Page 8: ...s a human health hazard However studies are still going forth and evidence continues to be examined Until the final conclusions of the research are reached you may wish to minimize your exposure to el...

Page 9: ...e de terre du sectionneur ou que la fiche du cordon est raccord e une prise correctement mise la terre D En effectuant les raccordements d entr e fixer d abord le conducteur de mise la terre appropri...

Page 10: ...r des v tements de protection d pourvus d huile tels que des gants en cuir une chemise en mat riau lourd des pantalons sans re vers des chaussures hautes et un couvre chef D Avant de souder retirer to...

Page 11: ...vrements et dispositifs de protection LE RAYONNEMENT HAUTE FR QUENCE H F risque de provoquer des interf rences D Le rayonnement haute frequence peut provoquer des interf rences avec les quipements de...

Page 12: ...champs magn tiques basse fr quence Le courant de soudage pendant son passage dans les c bles de sou dage causera des champs lectromagn tiques Il y a eu et il y a encore un certain souci propos de tels...

Page 13: ...0 To 210 ipm 0 To 5 3 mpm 1 8 To 7 32 in 3 2 To 5 6 mm 1 8 HP 70 RPM 115 VDC 1 5 A 17 in 0 43 m 17 1 2 lb 7 9 kg 2 2 Description 802 269 1 Motor drive Assembly This unit is a heavy duty wire feed ing...

Page 14: ...41 B 11 1 2 292 C 5 3 4 146 Inches Millimeters A 4 1 4 108 B 4 1 4 108 C 7 16 Dia 11 1 Dia 4 Holes 4 Holes A B C A B C 2 4 Typical Equipment Location ST 131 138 A 1 Welding Power Source 2 Gas Cylinder...

Page 15: ...ive Roll Remove drive rolls 5 Wire Guide Securing Screw Loosen wire guide screws 6 Anti Wear Guide 7 Inlet Wire Guide Install inlet wire guide into anti wear guide and secure with setscrew Install inl...

Page 16: ...tightly to keep it from unraveling WIRE ADVANCE V Weld Control Welding Power Source Set switches Pull and hold wire cut off end Push wire thru guide up to drive rolls continue to hold welding wire Pr...

Page 17: ...vice Clean Monthly OR Clean Drive Rolls 3 2 Brush Inspection And Replacement 802 269 S 0816 1 Motor 2 Brush Cap Remove brush cap 3 Brush Replace brush if it becomes chipped or broken or if less than 1...

Page 18: ...iner See gun torch Owner s Manual Remove weld spatter or foreign matter from around gun torch nozzle opening Check and secure motor plug connection check brushes Have Factory Authorized Service Agent...

Page 19: ...OM 1597 Page 15 SECTION 4 ELECTRICAL DIAGRAMS SA 192 940 Figure 4 1 Circuit Diagram For SWLR 115 SWLL 115 SWSR 115 And SWSL 115 SA 192 941 Figure 4 2 Circuit Diagram For SWLR 115E...

Page 20: ...Roll Wire Guide Kits Hardware is common and not available unless listed 1 2 3 1 2 3 5 6 7 8 9 23 24 25 28 29 30 31 32 33 34 35 36 37 38 39 40 41 1 2 3 1 2 3 5 6 4 4 7 12 14 15 16 17 18 19 20 21 22 26...

Page 21: ...200 WASHER lock stl split No 8 1 22 129 351 SCREW mach stl rdh 8 32 x 500 1 23 191 661 BRACKET right mount 1 23 191 662 BRACKET left mount 1 24 190 168 INSULATOR BOARD glastic 1 25 190 169 FACEPLATE...

Page 22: ...m 151 056 5 64 in 5 64 in 079 in 2 0 mm 151 057 3 32 in 3 32 in 094 in 2 4 mm 151 058 7 64 in 7 64 in 110 in 2 8 mm 151 059 1 8 in 1 8 in 125 in 3 2 mm 151 060 5 32 in 5 32 in 156 in 4 0 mm 3 16 in 3...

Page 23: ...ting Torches Remote Controls Accessory Kits Replacement Parts No labor Spoolmate 185 Spoolmate 250 Canvas Covers Miller s True Blue Limited Warranty shall not apply to 1 Consumable components such as...

Page 24: ...complete and retain with your personal records Always provide Model Name and Serial Style Number Call 1 800 4 A Miller or see our website at www MillerWelds com to locate a DISTRIBUTOR or SERVICE AGEN...

Reviews: