OM-823 Page 3

3.

Adjusting Amperage Or Voltage

.

On some welding power
sources, the front panel output

control setting does not matter

and the Remote Hand Control

adjusts the full range of the

welding power source output.

Ref. 122 023-A / Ref. 141 127-A / 039 411-D / Ref. 159 059 / Ref. 130 214-A

Example Of Remote Amperage Control Without Output (Contactor) Control

Set Switch

Set Control

Adjust Remote Amperage

Example Of Remote Amperage Control With Output (Contactor) Control

Min

(40 A)

Max

(200 A)

In Example: Min = 40 A In Range B,

Output = 120 A (50% of 40 to 200)

Max = 200 A In Range B 

Set Switches

Set Control

Min

(5 A)

Max

(200 A)

Place switch in On position for open-circuit

voltage. When switch is in Off position no

output is present.

In Example: Min = 5 A

Output = 200 A (100% of 5 to 200)

Max = 200 A