OM-1308 Page 5
SECTION 2 – INSTALLATION
2-1.
Specifications
Max. Open-
Amps Input at Rated Output, 50 or 60 Hz, Single-Phase
Rated Output
Circuit
Voltage
200 V
220 V
230 V
380 V
415 V
460 V
575 V
KVA
KW
250 A at 28 VDC,
40% Duty Cycle
200 A at 28 VDC,
60% Duty Cycle
32
50
2.3*
45
2.2*
44
2*
26
1.3*
24
1.2*
22
1*
18
0.8*
10
0.46*
7.7
0.13*
Wire Type and Diameter
Wire Feed Speed
Dimensions
Net Weight
Solid Steel
Stainless Steel
Flux Cored
50–670 IPM
H: 37 in (940 mm)
225 lb
.023 – .045 in
(0.6 – 1.2 mm)
.023 – .035 in
(0.6 – 0.9 mm)
.030 – .045 in
(0.8 – 1.2 mm)
(1.2–1.7 m/min)
W: 19 in (483 mm)
D: 30-1/4 in (768 mm)
(102 kg)
* While idling
2-2.
Duty Cycle And Overheating
4 Minutes Welding
6 Minutes Resting
6 Minutes Welding
4 Minutes Resting
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
voltage, or duty cycle before
welding.
Y
Exceeding duty cycle can
damage unit and void
warranty.
Overheating
0
15
A or V
OR
Reduce Duty Cycle
Minutes
duty1 4/95 – SB-150 215
40% Duty Cycle At 250 Amperes
60% Duty Cycle At 200 Amperes