OM-229 038 Page 11
3-7.
Electrical Service Guide
Migmatic Model
221
253
Input Voltage
220/230
230
400
Input Amperes at Rated Output
26
23
13
Max Recommended Standard Fuse or Circuit Breaker Rating in Amperes
26
23
13
** Input Conductor Size in mm
2
4
4
4
** Grounding Conductor Size in mm
2
4
4
4
** Power cord supplied with the unit is sized for 230V operation. Larger power cord may be required for cable lengths greater than 3 meters.
Consult national and local regulations.
3-8.
Selecting a Location and Connecting Input Power (1-Phase and 3-Phase)
A. 1-Phase
803 766-B
Y
Installation must meet all National
and Local Codes − have only quali-
fied persons make this installation.
Y
Disconnect and lockout/tagout in-
put power before connecting input
conductors from unit.
Y
Always connect green or green/
yellow conductor to supply
grounding terminal first, and never
to a line terminal.
1
Black And White Input Conductor
(L1 And L2)
2
Green Or Green/Yellow Grounding
Conductor
3
Input Power Cord.
4
Disconnect Device (switch shown in
the OFF position)
5
Disconnect Device Grounding
Terminal
6
Disconnect Device Line Terminals
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
Connect input conductors L1 and L2 to
disconnect device line terminals.
7
Over-Current Protection
Select type and size of over-current
protection using Section 3-7 (fused dis-
connect switch shown).
Close and secure door on disconnect
device. Remove lockout/tagout device,
and place switch in the On position.
4
3
L1
L2
1
=GND/PE
Earth Ground
2
1
5
6
7
Tools Needed:
18 in (457 mm)
for airflow
Summary of Contents for Migmatic 221
Page 23: ...OM 229 038 Page 19 Notes ...
Page 26: ...OM 229 038 Page 22 SECTION 7 PARTS LIST Figure 7 1 Wrapper Assembly All Models ...
Page 28: ...OM 229 038 Page 24 Figure 7 2 Main Assembly for Migmatic 221 ...
Page 30: ...OM 229 038 Page 26 Figure 7 3 Main Assembly for Migmatic 253 ...
Page 33: ...Notes ...
Page 34: ...Notes ...