OM-2225 Page 15
1
Output Control
2
Power Switch
Place controls as indicated. Only gas/air cir-
cuit is activated when the Power switch is
turned On with Output Control in Gas/Air Set
position.
3
Gas/Air Pressure Adjustment Knob
Pull knob and turn to adjust pressure. Push
knob in to lock setting.
Select desired cutting output with Output
Control.
4-2. Setting Gas/Air Pressure
Ref. 802 140 / Ref. 802 201-B
1
Set Controls
Turn On Gas/Air Supply
Adjust Pressure
On Unit
Select Desired
Amperage To Be-
gin Cutting
Set To 8
0 PSI
Requires
90
−
150 PSI Supply
Setting Gas/Air Pressure
Place Output Control in
Gas/Air Set Position
Power Switch On
Rear of
Unit
2