OM-2252 Page 22
SECTION 5
−
OPERATION
5-1. Controls
229 448-A
1
2
3
6
7
4
5
1
Power Switch
This unit is equipped with a fan motor that
is thermostatically controlled and only
runs when cooling is needed.
2
Voltmeter (see Section 5-2)
3
Ammeter (see Section 5-2)
4
Mode Switch
Use Mode switch to determine both process
and output On/Off control. Orange areas
highlight “contactor on” positions.
5
Panel/Remote Control Switch
For front panel control, place switch in Panel
position and use the V/A Adjust control to set
amperage or voltage, depending on Mode
switch selection.
For remote control, make connections to Re-
mote 14 receptacle (see Section 4-11), and
place switch in Remote position. In TIG
modes, output available through the remote
control is a percent of the V/A Adjust control
setting. Value selected on V/A Adjust control
is maximum output available through the re-
mote control. In the MIG, CC, and V-Sense
feeder modes, a remote control provides full
range of unit output regardless of V/A Adjust
control setting. A remote control is not func-
tional in Air-Carbon Arc or Stick modes. If
connection to Remote 14 receptacle is re-
moved and Panel/Remote control switch re-
mains in Remote position, output is controlled
with the V/A Adjust control.
6
V/A (Voltage/Amperage) Adjust Control
With Mode switch in any Stick or TIG position,
use control to adjust amperage from 5 to 500
amps. With Mode switch in a V-Sense Feeder
or MIG position, use control to adjust voltage
from 10 to 38 volts.
7
Inductance/Dig Control
Control adjusts Dig when a Stick or CC mode
is selected on mode switch. When set to-
wards minimum, short-circuit amperage at
low arc voltage is the same as normal welding
amperage. When set to max, control in-
creases short-circuit amperage at low arc
voltage. This allows the operator to use a
very short arc length without sticking the
electrode. As control is adjusted, the amount
of Dig selected is displayed on the amps me-
ter as a percentage (0 to 100%) of full range,
and
dig
is displayed on the volts meter.
When Air-Carbon Arc mode is selected, Dig
is internally set to max.
Control adjusts inductance when MIG or V-
Sense Feeder position is selected on mode
switch. Inductance determines the “wetness”
of the weld puddle. As setting is increased to-
wards maximum, “wetness” (puddle fluidity)
increases. As control is adjusted, the amount
of inductance selected is displayed on the
amps meter as a percentage (0 to 100%) of
full range, and
ind
is displayed on the volts
meter.
This control is not functional when one of the
TIG modes is selected.
Change control setting to best suite
application.
Summary of Contents for Dimension NT 450
Page 4: ...Notes ...
Page 14: ...OM 2252 Page 10 ...
Page 32: ...OM 2252 Page 28 SECTION 7 ELECTRICAL DIAGRAM Figure 7 1 Circuit Diagram For Dimension NT ...
Page 33: ...OM 2252 Page 29 218 081 F ...
Page 41: ...Notes ...