![Miller Electric Blue Star 3500 Owner'S Manual Download Page 27](http://html1.mh-extra.com/html/miller-electric/blue-star-3500/blue-star-3500_owners-manual_1796576027.webp)
OM-498 Page 23
Return To Table Of Contents
7-4.
Wiring Instructions For Optional 120/240 Volt Twistlock Plug (NEMA L14-30P)
plug3-11/99 − 802 527
1
Plug Wired For 120/240 V,
3-Wire Load
When wired for 120 V loads, each du-
plex receptacle shares a load with
one half of the 240 V receptacle.
2
Neutral (Silver) Terminal
3
Load 1 (Brass) Terminal
4
Load 2 (Brass) Terminal
5
Ground (Green) Terminal
6
Cord Grip
Strip cord jacket back enough to sep-
arate conductors.
Strip conductors enough to make
good contact with plug terminals.
Make plug connections and reinstall
outer shell and cord grip.
Tighten assembly screws onto shell.
Do not overtighten.
1
3
2
4
Tools Needed:
5
6
120 V
240 V
120V