OM-491 Page 10
3-2. Dimensions, Weights, And Operating Angles
Dimensions
F
Height
60 in (1524 mm)
(to top of muffler)
F
Width
28-1/2 in (724 mm)
(mtg. brackets turned in)
30-3/4 in (781 mm)
(mtg. brackets turned out)
Do not exceed operating angles while run-
ning or engine damage will occur.
Do not move or operate unit where it could
tip.
Depth
64-7/16 in (1637 mm)
A
64-7/16 in (1637 mm)
B
A
B
55-7/8 in (1419 mm)
B
C
9-1/2 in (241 mm)
D
27-1/2 in (699 mm)
G
30
°
E
1 in (25 mm)
G
30
°
30
°
F
28-1/2 in (729 mm)
Front Panel End
C
25
°
°
30
°
G
9/16 in (14 mm) Dia.
4 Holes
Front Panel End
E
25
°
Weight
E
D
w/ Perkins
3.152
No fuel: 1670 lb (758 kg)
w/fuel: 1860 lb (844 kg)
802 161-A
3-3. Volt-Ampere Curves
Ref. 193 017
The volt-ampere curve shows the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of all
other settings fall between the
curves shown.
0
20
40
60
80
100
0
100
200
300
400
500
600
700
DC AMPERES
DC VOL
TS
RANGES: 55
−
90
85
−
190
125
−
320
185
−
425
300
−
MAX