OM-1318 Page 11
SECTION 3 – INSTALLATION
3-1.
Installing Work Clamp
1
Insulator
2
Bolt
3
Smaller Hole
4
Work Clamp Tabs
Bend tabs around work cable.
5
Work Cable From Unit
6
Nut
1
2
3
4
5
6
Ref. ST-025 190-D
Tools Needed:
3/8, 7/16 in
3-2.
Installing Welding Gun And Changing Polarity
1
Drive Assembly
2
Gun Securing Bolt
3
Gun End
Loosen securing bolt. Insert gun
end through opening until it bottoms
against drive assembly. Tighten
bolt.
4
Gun Trigger Plug
Insert plug into receptacle, and
tighten threaded collar.
5
Jumper Links
Place jumper links in position
shown for desired polarity.
Close door.
Tools Needed:
2
1
3
4
Ref. ST-801 987
5/16 in
Straight Polarity
DCEN
Reverse Polarity
DCEP
Flux Cored Wires
(FCAW–Without Gas)
Solid Steel Or
Aluminum Wires
(GMAW–With Gas)
.
Follow wire manufacturer’s recommendation.