For more information, please visit www.devancocanada.com or call toll free at 855-931-3334
RLC-K36, RLC-K72
RELAY LIGHT CURTAIN
www.milleredge.com [email protected] 800-220-3343 3/4
RLC-K36
RLC-K72
PHYSICAL
Max. Protection Height
36 in. (~1 m)
72 in. (~2 m)
Dimensions
1 W x 38 H x 1.1 D in. (25 mm x ~1 m x 28 mm)
1 W x 74 H x 1.1 D in. (25 mm x ~2 m x 28 mm)
Weight
32 oz.
64 oz.
Housing Material
PVC over aluminum
PVC over aluminum
Temperature Range
-40°F to +140°F (-40°C to +60°C)
-40°F to +140°F (-40°C to +60°C)
LED Indicators
EM: Power, Obstruction
RX: Power
EM: Power, Obstruction
RX: Power
Cable Length
EM: 50 ft. (~15 m)
RX: 50 ft. (~15 m)
EM: 50 ft. (~15 m)
RX: 50 ft. (~15 m)
Mounting
(4) Universal mounting brackets
(6) Universal mounting brackets
Degree of Protection
IP67
IP67
IV.
MODELS
RLC-K36
: 3 ft., 8 elements, non-monitored/fail safe
RLC-K72
: 6 ft., 16 elements, non-monitored/fail safe
V.
COMPLIANCE
The RLC-K36 and RLC-K72 are not approved for use as external entrapment protection devices for garage
doors. For post-2010 operators, please leave the external entrapment protection intact.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which may
be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
1.
Re-orient or relocate the receiver antenna
2.
Increase the separation between the equipment and the receiver
3.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
4.
Consult the dealer or an experienced radio/TV technician for help
Changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
VI.
MAINTENANCE
It is strongly recommended that users check photo optics at least once per month for low batteries alerts (where
applicable) and damage to housings and mountings. Also check for signs of damage to cables or connection
points. Refer to your operator manual for detailed instructions about motor connections.
VII.
REPLACEMENT
To replace your Miller Edge photo optic, contact your sales representative. Attempting to repair your Miller Edge
photo optic is not recommended and will void the manufacturer warranty.
VIII.
WARRANTY
The Relay Light Curtain carries a
2-year
warranty
from date of shipment from Miller Edge for credit or
replacement. This warranty applies to normal use, which is found to have defective materials or workmanship, as
determined solely by an authorized factory representative. This warranty is void where evidence of misuse or
abuse is present. This warranty covers repair or replacement of the purchased product only; product
installation/labor charges are not covered. Miller Edge manufactures its products to meet stringent specifications
and cannot assume responsibility for those consequences arising from improper installation or misuse. Installation