Miller Edge RBAND Installation Instructions Manual Download Page 2

www.milleredge.com        [email protected]        800-220-3343

IMAGE 2.  RBAND GATE EDGE RECEIVER PCB & CONNECTIONS

LED INDICATORS 

Initial Power
• 

No Transmitters Programmed:  
R1 & R2 LEDs 

on

R1 or R2 LED
• 

Programmed: 

Off

• 

Fault Condition: 

On

R3 LED
• 

On when battery is low

A TEST LED 
• 

On when in test mode

CHECK LED  
(both channels programed)
• 

Programmed: Check LED flashes every 
5 seconds

DIP SWITCH SETTINGS

ON

1 2 3 4

 

Switch 1-3: Leave switches in factory 
default settings

 

Switch 4: Used to enable Normally Closed 
cycle testing: 
• 

N.C. Operator: Set to 

on and connect 

the switched power to the 

A Test and 

Common pins shown above

• 

10K Operator: Set to 

off

TABLE 1.  
REMOVABLE CONNECTORS 

For Normally Closed gate operators,  
please reference page 5. 

8-PIN CONNECTOR

Power

+12/24 AC/DC 

„ 

Constant power source

-12/24 AC/DC

 

„ 

Constant power source (ground)

Relay Output 1 

CS1

 

„ 

N.C. monitored input 

C1

 

„ 

Monitored input Common 

BS1

 

„ 

10K monitored input 

Relay Output 2

CS2

 

„ 

N.C. monitored input

C2

 

„ 

Monitored input Common

BS2

 

„ 

10K monitored input

4-PIN CONNECTOR

Relay Output 3

NO3

 

„ 

Low battery alarm (optional)

C3

 

„ 

Low battery alarm (optional)

N.C. Power Cycling

COM.

 

„ 

COM: Switched power Common 

A TEST

 

„ 

+12/24VDC: Switched power  

 

 source

GND ANT

R2

R1

R3 A TEST

CHECK

PROG

ON

1 2 3 4

12/24 AC/DC

CS1 C1

+

-

BS1

CS2 C2

BS2

NO3

C3

COM. A TEST

MR

PROGRAM 

BUTTON

CHECK LED  

&  BUTTON

REMOVABLE 

8-PIN CONNECTOR

DIP SWITCHES

RELAY 

LEDS

ANTENNA  

TERMINAL 

BLOCK

REMOVABLE 

4-PIN CONNECTOR

COAXIAL CABLE 
PROVIDED BY 
INSTALLER

ANTENNA

F-CONNECTOR  

COAX EXTENDER

Summary of Contents for RBAND

Page 1: ...ommended Multi meter capable of reading 10KΩ Mounting screws for the Receiver 2 RECEIVER INSTALLATION 2 1 Remove operator cover and turn off the power to the gate operator 2 2 Determine where to place the external mounted antenna so it is in line of sight with the Transmitter for the entire range of travel IMAGE 1 Prepare the antenna coax as necessary 2 3 Remove Receiver cover and mount the base i...

Page 2: ...OVABLE CONNECTORS For Normally Closed gate operators please reference page 5 8 PIN CONNECTOR Power 12 24 AC DC Constant power source 12 24 AC DC Constant power source ground Relay Output 1 CS1 N C monitored input C1 Monitored input Common BS1 10K monitored input Relay Output 2 CS2 N C monitored input C2 Monitored input Common BS2 10K monitored input 4 PIN CONNECTOR Relay Output 3 NO3 Low battery a...

Page 3: ...oting the alignment pin IMAGE 3 4 2 Test the sensing edge for functionality 5 TROUBLESHOOTING If the Receiver does not react to the Transmitter you can check the RF signal strength 5 1 Press the check button on the Receiver for 2 seconds IMAGE 2 4 beeps will be heard You then will hear a beep every 1 1 2 seconds during the check process Wait about 30 seconds if no other beeps occur your system is ...

Page 4: ...ditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This device complies with FCC radiation exposure limits for an uncontrolled environment This device shall be installed and operated with a minimum distance of 0 4 between users or bystanders and the device RBand Receiver Model RB...

Page 5: ...ON COMMON MON 12 VDC ON 1 2 3 4 DIP Switch 4 Turn to on HySecurity CS1 C1 BS1 CS2 C2 BS2 NO3 C3 COM ATEST 12 24 AC DC 24 VDC COMMON S1 S2 S3 SENSOR COM S1 S2 S3 SENSOR COM SENSOR COM 24 VDC ON 1 2 3 4 DIP Switch 4 On to run Off to test Not Sensor Common Maximum Controls CS1 C1 BS1 CS2 C2 BS2 NO3 C3 COM ATEST 12 24 AC DC 12 or 24 VDC GND EDGE 1 GND EDGE 2 GND GND 12 VDC ON 1 2 3 4 DIP Switch 4 Turn...