![Miller Edge RBAND Installation Instructions Manual Download Page 2](http://html.mh-extra.com/html/miller-edge/rband/rband_installation-instructions-manual_1796356002.webp)
www.milleredge.com [email protected] 800-220-3343
IMAGE 2. RBAND GATE EDGE RECEIVER PCB & CONNECTIONS
LED INDICATORS
Initial Power
•
No Transmitters Programmed:
R1 & R2 LEDs
on
R1 or R2 LED
•
Programmed:
Off
•
Fault Condition:
On
R3 LED
•
On when battery is low
A TEST LED
•
On when in test mode
CHECK LED
(both channels programed)
•
Programmed: Check LED flashes every
5 seconds
DIP SWITCH SETTINGS
ON
1 2 3 4
Switch 1-3: Leave switches in factory
default settings
Switch 4: Used to enable Normally Closed
cycle testing:
•
N.C. Operator: Set to
on and connect
the switched power to the
A Test and
Common pins shown above
•
10K Operator: Set to
off
TABLE 1.
REMOVABLE CONNECTORS
For Normally Closed gate operators,
please reference page 5.
8-PIN CONNECTOR
Power
+12/24 AC/DC
Constant power source
-12/24 AC/DC
Constant power source (ground)
Relay Output 1
CS1
N.C. monitored input
C1
Monitored input Common
BS1
10K monitored input
Relay Output 2
CS2
N.C. monitored input
C2
Monitored input Common
BS2
10K monitored input
4-PIN CONNECTOR
Relay Output 3
NO3
Low battery alarm (optional)
C3
Low battery alarm (optional)
N.C. Power Cycling
COM.
COM: Switched power Common
A TEST
+12/24VDC: Switched power
source
GND ANT
R2
R1
R3 A TEST
CHECK
PROG
ON
1 2 3 4
12/24 AC/DC
CS1 C1
+
-
BS1
CS2 C2
BS2
NO3
C3
COM. A TEST
MR
PROGRAM
BUTTON
CHECK LED
& BUTTON
REMOVABLE
8-PIN CONNECTOR
DIP SWITCHES
RELAY
LEDS
ANTENNA
TERMINAL
BLOCK
REMOVABLE
4-PIN CONNECTOR
COAXIAL CABLE
PROVIDED BY
INSTALLER
ANTENNA
F-CONNECTOR
COAX EXTENDER