www.milleredge.com [email protected] 800-220-3343
3/5
IMAGE 2. RBAND GATE EDGE RECEIVER PCB & CONNECTIONS
LED INDICATORS
R1 & R2 RELAY LEDS
• O
n:
No transmitters programmed
• Off
: Programmed
• On
(transmitters programmed):
Fault condition
R3 RELAY LED
• On
when battery is low
A TEST LED
• On
when in
test
mode
CHECK LED
(both channels programed)
•
Programmed: Check LED flashes
every 5 seconds
DIP SWITCH SETTINGS
ON
1 2 3 4
Switch 1-3:
Leave switches in factory
default settings
Switch
4:
Used to enable Normally
Closed cycle testing:
•
10K Operator: Set to
off
•
N.C. Operator: Set to
on
and
connect the switched power to the
A Test
and
Common
pins shown
above [TABLE 2]
GND ANT
R2
R1
R3 A TEST
CHECK
PROG
ON
1 2 3 4
12/24 AC/DC
CS1 C1
+
-
BS1
CS2
C2
BS2
NO3
C3
COM. A TEST
MR
PROGRAM
BUTTON
CHECK LED
& BUTTON
REMOVABLE
8-PIN CONNECTOR
DIP
SWITCHES
RELAY
LEDS
ANTENNA
TERMINAL
BLOCK
REMOVABLE
4-PIN CONNECTOR
COAXIAL CABLE
PROVIDED BY
INSTALLER
ANTENNA
F-CONNECTOR
COAX EXTENDER
MR