background image

www.milleredge.com        [email protected]        800-220-3343        

3/5

IMAGE 2.  RBAND GATE EDGE RECEIVER PCB & CONNECTIONS

LED INDICATORS 

R1 & R2 RELAY LEDS

• O

n: 

No transmitters programmed

• Off

: Programmed

• On 

(transmitters programmed): 

Fault condition

R3 RELAY LED
• On

 when battery is low

A TEST  LED 
• On

 when in 

test

 mode

CHECK LED  

(both channels programed)
• 

Programmed: Check LED flashes 
every 5 seconds

DIP SWITCH SETTINGS

ON

1 2 3 4

 

Switch 1-3:

 Leave switches in factory 

default settings

 Switch 

4:

 Used to enable Normally 

Closed cycle testing: 

• 

10K Operator: Set to 

off

• 

N.C. Operator: Set to 

on

 and 

connect the switched power to the 

A Test

 and 

Common

 pins shown 

above [TABLE 2]

GND ANT

R2

R1

R3 A TEST

CHECK

PROG

ON

1 2 3 4

12/24 AC/DC

CS1 C1

+

-

BS1

CS2

C2

BS2

NO3

C3

COM. A TEST

MR

PROGRAM 

BUTTON

CHECK LED  

&  BUTTON

REMOVABLE 

8-PIN CONNECTOR

DIP

SWITCHES

RELAY 

LEDS

ANTENNA  

TERMINAL 

BLOCK

REMOVABLE 

4-PIN CONNECTOR

COAXIAL CABLE 
PROVIDED BY 
INSTALLER

ANTENNA

F-CONNECTOR  

COAX EXTENDER

MR

Summary of Contents for RBand RB-TX10

Page 1: ...0 RBand Gate Edge Receiver RB G RX10 Receiver antenna 2 3 6V AA lithium batteries 4 6 pan head transmitter mounting screws RB TX10 Contents RBand Gate Edge Transmitter RB TX10 2 3 6V AA lithium batteries 4 6 pan head transmitter mounting screws Replacement 3 6V AA lithium batteries can be purchased at your local electronics store or via Miller Edge Required 1 8 flat blade screwdriver 1 4 flat blade ...

Page 2: ...put 4 PIN CONNECTOR Relay Output 3 NO3 f Low battery alarm optional C3 f Low battery alarm optional N C Power Cycling COM f COM Switched power Common A TEST f 12 24VDC Switched power source TABLE 2 NORMALLY CLOSED OPERATORS Removable Connector Assignments by Manufacturer HySecurity ON 1 2 3 4 DIP Switch 4 On to run Off to test CS1 C1 BS1 CS2 C2 BS2 NO3 C3 COM ATEST 12 24 AC DC SENSOR COMMON COMMON...

Page 3: ... DIP SWITCH SETTINGS ON 1 2 3 4 Switch 1 3 Leave switches in factory default settings Switch 4 Used to enable Normally Closed cycle testing 10K Operator Set to off N C Operator Set to on and connect the switched power to the A Test and Common pins shown above TABLE 2 GND ANT R2 R1 R3 A TEST CHECK PROG ON 1 2 3 4 12 24 AC DC CS1 C1 BS1 CS2 C2 BS2 NO3 C3 COM ATEST MR PROGRAM BUTTON CHECK LED BUTTON ...

Page 4: ... of outer covering of sensing edge cable then feed through the Transmitter strain relief fitting Connect the two sensing edge wires to the removable terminal Dress the wires with a small service loop and tighten the strain relief Mount unit utilizing the mounting holes at the 4 corners of the Transmitter box Affix lid to the Transmitter noting the alignment pin IMAGE 3 Note Altering the NEMA 4 Trans...

Page 5: ... BS2 10K termination Relay Output 3 2 Relay closes when low battery is detected A TEST 2 Connect to switched DC power and Com for N C monitoring 8 FCC COMPLIANCE RBAND EDGE TRANSMITTER Model RB TX10 5 7 5 7 FCC ID U5Z RB TX10 U5Z RB TX10B U5Z RB TX10C This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interfer...