background image

TCL-2

READ THIS FIRST!  

 

 

 

 

 

Any changes or modifications not expressly approved by MILLENNIA MEDIA, INC. could 

void your authority to operate this equipment under the EC or FCC rules. 

1. Copyright: You acknowledge that no title to the intellectual property in the TCL-2 is trans-

ferred to you. 

2. Inspection: Inspect packing boxes, TCL-2, and cables for damage, unusual marks, or short-
ages. It is your responsibility to report damage, shortage, or misshipments in a timely manner.  

Millennia Media and/or its dealers will not be responsible for claims arising from damage in 

shipping, nor will claims for shortage or misshipments be honored, more than 10 days after 
ship date.

3. Read this manual carefully and completely before attempting to use the TCL-2. Improper 

operation could result in damage to product. It is the user's responsibility to understand the safe 

use and operation of this device.

4. The shipping box of the TCL-2 system will include (1) Owner's Manual, (2) TCL-2, (3) a UL 
approved power cord (110 V units only), (4) Owner's Registration Card. Fill out the Owner's 
Registration Card and return to Millennia Media at your earliest ability.

The material contained in this manual consists of information that is property of Millennia 
Media, Inc. and is intended solely for use by the purchasers of the equipment described in this 
manual. Millennia Media, Inc. expressly prohibits the duplication of any portion of this manual 
or the use thereof for any purpose other than the operation and/or maintenance of the equip-
ment described in this manual without the express written permission of Millennia Media, Inc.. 
Under copyright laws, this manual may not be duplicated in whole or in part without the writ-
ten consent of Millennia Media, Inc..  

TCL-2 and Twin Topology are trademarks of Millennia Media, Inc.  All other trademarks are 
property of their respective holders. Serial numbers are located on the rear left side of each 
unit. We suggest that you record the serial numbers in the space provided below. Refer to it 
whenever you call an authorized Millennia Media repair facility or the manufacturer. Make sure 
that you return your completed warranty card immediately. 

Features and specifications subject to change without notice.
© 2007 Millennia Media, Inc., All rights reserved

Serial Nos. ______________________________________________________________

Purchase Date ___________________________________________________________

Where Purchased _________________________________________________________

Summary of Contents for TCL-2

Page 1: ...l contained in this manual consists of information that is property of Millennia Media Inc and is intended solely for use by the purchasers of the equipment described in this manual Millennia Media Inc expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation and or maintenance of the equip ment described in this manual without th...

Page 2: ... on or pinched by having objects placed on it Pay particular attention to plugs receptacles and the point where the AC power cord exits the TCL 2 4 GROUNDING For your safety it is extremely important that the grounding pin of the 3 wire power cable in cluded with unit be inserted into a grounding type 3 pin power outlet If you are unable to insert the plug into an existing outlet contact an electr...

Page 3: ...ure that the rear panel voltage selection fuse block switch is set correctly In the USA the TCL 2 is shipped with the voltage selection block set to 100 120 VAC At this voltage setting a pair of 1 amp 5 x 20 mm slow blow fuses have been factory installed If you change the voltage selection block to 200 240 VAC usage be sure to change both fuses to 500 milliamp 0 4 amp slow blow types The TCL 2 enc...

Page 4: ...The fuse block contains two fuses one fuse is in series with the hot power line while the other fuse is in series with the neutral power line Both fuses must be installed To change the mains voltage selection remove IEC power connector and assure that the TCL 2 is not connected to mains power With a non conductive tool gently pry the fuse block away from the power entry module Remove the two fuses...

Page 5: ... TCL 2 1 2 4 5 3 GROUND LIFT PUSH PUSH 115 IN 2 OUT 2 IN 1 OUT 1 TCL 2 Twincom Rear Panel ______________ 1 2 4 5 3 ...

Page 6: ...ch selects channel status When switch is depressed and corresponding LED is illuminated audio signal will be processed by dynamics functions When switch is not depressed and LED is not illuminated audio signal is not processed by dynamics functions This is not a hard wire bypass Audio signal is always in the active circuit path regardless of this switch s status 6 METER FUNCTION SELECT SWITCH METE...

Page 7: ... TCL 2 TCL 2 Twincom Rear Panel ______________ ...

Page 8: ... desired about of GR as shown on the meter E Depress the Stereo Link switch Note the amount of GR shown on the meter will probably decrease Simply increase the threshold until you again achieve the desired about of GR as shown on the meter F You should now see the same amount of GR on BOTH meters If you do not adjust the ratio control s on one or both channels until you do 10 METER ZERO ADJUST MET...

Page 9: ... ohms VT or SS 5 ohms 300 ohms 300 ohms SS 3 000 ohms VT 87 dBu SS 82 dBu VT 50 dB 75 dB typical lOOmV to 20 kHz Pin 2 positive polarity Pin 1 ground 20 dBu to 20 dBu continuously adjustable 2 mS to 100 mS continuously adjustable 00 mS to 3 0 sec continuously adjustable Min 1 4 to 1 Max 30 to 1 continuous Yes Yes Yes Switch In FET Amplifiers Switch Out Vacuum Tube Amplifiers ELECTRO MECHANICAL SPE...

Page 10: ... goal of absolute sonic neutrality and timbre purity 1 No audio transformers The vast majority of professional vacuum tube audio equipment uses audio transformers Yet as someone once said there is no transformer that sounds like no transformer For this reason Millennia avoids audio path transformers and relies on other less colorful coupling techniques 2 Lower tighter gain and threshold structure ...

Page 11: ...PUT LEVEL OUTPUT LEVEL CH IN CH IN METER ON GR METER ON GR STEREO LINK TT TT VU 20 10 7 5 3 3 2 2 1 1 0 VU 20 10 7 5 3 3 2 2 1 1 0 Millennia Music Media Systems TCL 2 Template DATE PROJECT STUDIO ARTIST SONG LOG NOTES Millennia Music Media Systems 4200 B Day Spring Ct Placerville CA 95667 USA T 530 647 0750 F 9921 E MAIL info mil media com WEB http www mil media com This page can be downloaded fro...

Page 12: ...CLUSIONS There are no express warranties except as listed above Millennia Media shall not be liable for special subsequent incidental consequential or punitive damages including but not limited to damage to recordings microphones mixing consoles or any associated equipment down time costs loss of goodwill or claims of any party dealing with purchaser for such damages re sulting from the use of thi...

Reviews: