5. Network Configuration
This chapter explains how to connect UR75 to network via WAN connection or cellular.
5.1 Ethernet WAN Configuration
A. Go to “Network > Interface > WAN” to configure WAN parameters. Take static IP configuration as an
example. DHCP client and PPPoE type are optional according to your requirements.
Click “Save & Apply” button to make the changes take effect.
B. Connect WAN port to another router or modem.
C. Log in UR75 web GUI via WAN port IP address and go to “Status > Network” to check if status is “up”.
D. Go to “Network > Interface > Link Failover” to rise the WAN priority to 1.