Installation Guide: MIL-C2414
6
3
Indicators
There are four LEDs, including:
•
TP/ACT
: Unit is receiving packets from the 100BASE-
TX port
•
FX/ACT
: Unit is receiving packets from the 100BASE-
FX port
•
TP/LINK
: There is an active connection on the
100BASE-TX port
•
FX/LINK
: There is an active connection on the
100BASE-FX port
S p e c i fi c a t i o n s
RJ-45: MDI
RJ-45: MDI-X
Fiber Specifications: SC connector
1300 nm multi-mode fiber
• 62.5/125 micron diameter
• Launch power: -14 dBm
• Receive sensitivity: -31 dBm
• Supports half- and full-duplex modes
I n s t a l l a t i o n
Do the following to install the MIL-C2414 Series into a
redundant rack mount chassis:
1. Make any configuration changes to the module (i.e.,
DIP switch settings or jumper).
2. Remove the screws securing the faceplate and
remove it from the chassis.
3. Slide the module into the slot through the guide
rails.
4. Insert the module into the card-edge connector (port
bay). Make sure it is seated firmly.
5. Secure the module with the two thumbscrews
located on the faceplate of the unit.
The unit is now ready for network connections.
MDI/MDI-X Switch
The MDI/MDI-X switch allows for quick configuration
of the 100BASE-TX port. Cables used when the switch is
in the MDI-X position (the “left” position):
• For a hub/repeater, use a swap cable (pins are
connected 1 to 3, 2 to 6, 3 to 1, and 6 to 2)
Pin 1=TD+
Pin 2=TD-
Pin 3=RD+
Pin 6=RD-
Pin 1=RD+
Pin 2=RD-
Pin 3=TD+
Pin 6=TD-
1 2
3 4
5 6
8
7