Addendum 1 14/7/2021 to MIL-Solar Eclipse series Installation and Operation Manual PNo 6569 Rev 6
Page
3
of
5
1. Australian Grid Settings
The Eclipse inverter is designed and made in Australia by MIL-Systems Pty Ltd with the brand MIL-Solar.
The Eclipse inverter is not imported and is only for the Australian market. The Eclipse has the standard
Australian grid settings and not user or installer settings or adjustments are needed for Australia. The
Eclipse inverter is Australian designed and made for the Australian grid.
2. Power Quality Response Settings
The Eclipse inverter is designed and made with the Australian standard AS4777.2:2015 power quality
response requirements.
The Eclipse inverter is capability to contribute to maintaining the power quality at the point of connection or to
provide support to a grid. The volt response mode is to vary the output power of the inverter in response to
the voltage at its terminals.
To enable, disable and adjust the Power Quality Response Modes the installer needs a user name and
password. This is available by contacting
.
The installer can access the Eclipse inverter Power Quality Response Modes via the Eclipse wifi interface,
see page 28 of this manual.
The installer uses the wifi user interface Installation Page to access the Power Quality Response Modes, see
page 38 of this manual.
The installer can check and adjust the Volt-Var, Volt-Watt and Power Rate modes and set points by going to
the Power Quality Mode page from the Installation Page.
Power derating for voltage variation (Volt-Watt mode)
The Eclipse inverter power output will vary in response to the AC grid voltage. This is normally on from MIL-
Systems factory. This mode has settings that can be adjusted by the installer.
Reactive power regulation for voltage variation (Volt-VAr mode)
The Eclipse reactive power will vary in response to the AC grid voltage. This is normally off from MIL-
Systems factory. This mode has settings that can be adjusted by the installer.