background image

RB912UAG-series

This manual covers RouterBOARD 912UAG series models: 

RB912UAG-5HPnD

RB912UAG-2HPnD

Safety Warnings

Before you work on any equipment, be aware of the hazards involved with electrical circuitry, and be familiar with standard practices for preventing 

accidents.

Read the installation instructions before connecting the system to the power source.

This equipment is to be installed by trained and qualified personnel, as per these installation instructions. The installer is responsible for obtaining any 

required local or national safety inspections of the structural integrity of the installation by the local authority/inspection department.

All installation methods for mounting an access point on any wall surface are subject to the acceptance of local jurisdiction.

The Installation of the equipment must comply with local and national electrical codes.

Please read the mounting instructions carefully before beginning installation.

Failure to use the correct hardware and configuration or to follow the correct procedures could result in a hazardous situation to people and damage to the 

system.

We cannot guarantee that no accidents or damage will occur due to the improper use of the device. Please use this product with care and operate at your 

own risk.

This is a class A device. In a domestic environment, this product might cause radio interference in which case the user might be required to take adequate 

measures.

Mounting

912UAG series router for professional use. Each of the devices comes in ESD protective packaging. When handling electrical equipment please observe 

the following safety precautions:

use a wrist grounding strap when unpacking and working with electrical components to avoid electrical discharge (ESD) damage,

after unpacking please place the router on the anti-static mat,

when mounting unit make sure there are no objects that can damage or touch the PCB plate,

note that ETH, USB port and DC jack are extending over the perimeter of the PCB plate.

The device can be mounted in your desired location using the factory provided four holes in a PCB plate, located on each side of the device.
Warning! This equipment should be installed and operated with a minimum distance of 380 cm between the device and your body. Operation of this 
equipment in the residential environment could cause radio interference.

Connecting

1. Choose your powering solution, please see 

 section for possibilities.

Powering

2. If needed, connect accessories to the miniPCIe slot, antenna cables to the miniPCIe card and insert SIM

card.

3. Connect your ethernet cable to the gigabit ethernet port.

4. Connect your direct input power jack if not using POE, to start up the device.

5. The device will boot up and after short beep Wireless network will be available for connecting.

6. Open network connections on your pc, mobile phone or other device and search for MikroTik wireless

network and connect to it.

7. Once connected to the wireless network, open 

 in your web browser to start

https://192.168.88.1

configuration, since there is no password by default, you will be logged in automatically.

8. We recommend clicking the "Check for updates" button and updating your RouterOS software to the latest

version to ensure the best performance and stability.

9. Choose your country, to apply country regulation settings and set up your password in the screen that

loads.

Summary of Contents for RB912UAG Series

Page 1: ... please observe the following safety precautions use a wrist grounding strap when unpacking and working with electrical components to avoid electrical discharge ESD damage after unpacking please place the router on the anti static mat when mounting unit make sure there are no objects that can damage or touch the PCB plate note that ETH USB port and DC jack are extending over the perimeter of the P...

Page 2: ...n for RB912UAG 5HPnD 2 4 GHz 802 11b g n for RB912UAG 2HPnD Reset button The reset button has three functions Hold this button during boot time until LED light starts flashing release the button to reset RouterOS configuration total 5 seconds Keep holding for 5 more seconds LED turns solid release now to turn on CAP mode The device will now look for a CAPsMAN server total 10 seconds Or Keep holdin...

Page 3: ...stry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux d...

Page 4: ...cia incluyendo la que pueda causar su operacion no deseada Fabricante Mikrotikls SIA Brivibas gatve 214i Riga LV 1039 Latvia País De Origen Letonia Lituania China Republica Popular Estados Unidos De America Mexico Por favor contacte a su distribuidor local para preguntas regionales específicas La lista de importadores se puede encontrar en nuestra página de inicio https mikrotik com buy latinameri...

Page 5: ...cy Selection DFS requirements All Mikrotik radio devices must be professionally installed This MikroTik device meets Maximum WLAN transmit power limits per ETSI regulations For more detailed information see Declaration of Conformity above Dieses MikroTik Gerät erfüllt die maximalen WLAN Sendeleistung Grenzwerte gemäß ETSI Bestimmungen Weitere Informationen finden Sie oben unter Konformitätserkläru...