background image

CRS328-4C-20S-4S+RM

Quick start

Mount unit in a rackmount cabinet or place on the flat surface (see 

Mounting

).

Connect two powering units to the AC source using power cords.

The Initial connection has to be done via the Ethernet cable, using the MikroTik Winbox utility.

Use Winbox to connect to the default IP address of 192.168.88.1 from any port, with the username 

admin

and no password.

We recommend clicking the “Check for updates” button and updating your RouterOS software to the latest
version to ensure the best performance and stability.

Set up your password to secure the device.

Powering

The device accepts powering from two IEC connectors. AC input range 100-240 V  .

The power consumption under maximum load can reach 43 W.

Booting process

The device supports booting RouterOS (for routing and switching configuration) or SwOS (for only using as a 
switch). By default, the device will boot RouterOS, but you can reboot into the other operating system in the 
following ways: 

From SwOS: In the System menu, click the “Boot RouterOS” button on the bottom of the page.

From RouterOS: in the System, RouterBOARD menu, click “Settings” and there select “Boot OS”.

It is also possible to select the OS and configure other boot settings via the serial console menu. 

Configuration

Full RouterOS and SwOS documentation is located here: 

http://mt.lv/help

This device is not preconfigured other than an IP address on the bridge interface. You can connect from any port,
as   all   ports   are   switched   together   by   default.   Another   configuration   has   to   be   applied   according   to   the
documentation manual linked above.
The Initial connection has to be done via the Ethernet cable, using the MikroTik WinBox utility. WinBox should be
used   to   connect   to   the   default   IP  address   of   192.168.88.1   from   any   port,   with   the   username   admin   and   no
password.
For recovery purposes, it is possible to boot the device for reinstallation, see Buttons and jumpers.
In case the IP connection is not available, the WinBox utility can also be used to connect to the MAC address of the
the device. Applies only when device has booted RouterOS.
The device is equipped with an RJ45 serial port, set by default to 115200 bit/s, 8 data bits, 1 stop bit, no parity.
Standard RJ45 to COM cable can be used, pinout can be found here: 

http://mt.lv/console

Extension slots and ports

20 SFP ports.

4 SFP+ ports, which accept both 1.25 Gb SFP and 10 Gb SFP+ modules.

4 combo ports, consisting of four twisted pair (T) sockets and four SFP sockets (F). 

RJ45 serial port.

Please visit wiki pages for MikroTik SFP module compatibility table: 

https://wiki.mikrotik.com/wiki/MikroTik_SFP_module_compatibility_table

 

See mikrotik.com/products for the latest version of this document.

Page 1, Document #52503 Modified on: 07.OKT.2019

Summary of Contents for CRS328-4C-20S-4S+RM

Page 1: ...l RouterOS and SwOS documentation is located here http mt lv help This device is not preconfigured other than an IP address on the bridge interface You can connect from any port as all ports are switched together by default Another configuration has to be applied according to the documentation manual linked above The Initial connection has to be done via the Ethernet cable using the MikroTik WinBo...

Page 2: ...t can be placed on the desktop Please attach rubber pegs on the bottom of the router if the desired placement is on the flat surface or use a Phillips screwdriver to attach rackmount ears on both sides of the device if designated use is for rackmount enclosure 1 Attach rack ears to both sides of the device and tighten four screws to secure them in place as shown in the picture 2 Place the device i...

Page 3: ...d to the device Useful for RouterBOOT debugging and recovery Mode button The action of the mode button can be configured from RouterOS software to execute any user supplied RouterOS script For configuration use the menu system routerboard mode button Specifications For more information about this product specifications pictures downloads and test results please visit our web page https mikrotik co...

Page 4: ...odifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation...

Page 5: ...tiva 2014 53 UE Il testo completo della dichiarazione di conformità UE è disponibile al seguente indirizzo Internet https mikrotik com products IS Hér með lýsir Mikrotīkls SIA því yfir að RouterBOARD er í samræmi við grunnkröfur og aðrar kröfur sem gerðar eru í tilskipun 2014 53 EU Fullur texti ESB samræmisyfirlýsingar er að finna á eftirfarandi veffangi https mikrotik com products LT Aš Mikrotīkl...

Page 6: ...ðu 192 168 88 1 í vafra til að stilla það Nánari upplýsingar á http mt lv help is NO Instruksjonsmanual Koble strømadapteren for å slå på enheten Åpne 192 168 88 1 i nettleseren din for å konfigurere den Mer informasjon på http mt lv help no LT Naudojimosi instrukcija Prijunkite maitinimo adapterį įjunkite įrenginį Į interneto naršyklę 192 168 88 1 Atidarykite galite konfigūruoti gaminį Daugiau in...

Reviews: