background image

 

19 
 

 

RTU300 SERIES 

 HARDWARE MANUAL 

1.13

 

Analog Outputs 

 

Board Type: 

GA1, GA4 

Module Output: 

2 Channel 

Analog Output Type: 

0-20 mA, 4-20 mA 

Analog Output Resolution: 

12 Bit 

Current Output Precision: 

%1 Precision 

Common Output GND: 

1 GND (2 Point / Common) 

 

 

 

Figure 14 RTU300 Analog Output Connection Diagram 

 

 

 

Summary of Contents for RTU Series

Page 1: ...RTU300 HARDWARE MANUAL RTU301 RTU310 RTU320 RTU330 RTU340 RTU Series 04 2022 MIKRODEV_HM_RTU300_EN v1 2...

Page 2: ...oard Type Physical Interface 8 1 3 GA4 Board Type Physical Interface 9 1 4 GA5 Board Type Physical Interface 10 1 5 GA6 Board Type Physical Interface 11 1 6 GA7 Board Type Physical Interface 12 1 7 Ge...

Page 3: ...face 11 Figure 7 GA6 Board Type Connector and Physical Interface 12 Figure 8 GA7 Board Type Connector and Physical Interface 12 Figure 9 RTU300 Power Connection Diagram 19 Figure 10 RTU300 Digital Inp...

Page 4: ...60870 DNP3 and MODBUS TCP protocols With its easy flexible and fast programming capabilities and expandable I O capability up to 1024 points Mikrodev RTU products are preferred for electrical applicat...

Page 5: ...y the industrial automation industry and the quality of our products are proved on the field for many years MIKRODEV is one of the few companies in the world that has its own designed IEC 61131 3 comp...

Page 6: ...e the device under conditions other than the environmental conditions specified in the Electrical Specifications section humidity dust liquid and temperature etc Removing the warranty label on the pro...

Page 7: ...when a lightly force is applied to the lower part the device locates into the DIN rail easily and the montage is completed See Figure 1 Figure 1 DIN Rail Mounting Expansion Installation Assembly betwe...

Page 8: ...ction 19 USB Port 5 RS485 Connections 20 Relay Status Information LED 6 RS232 GND Connections 21 Digital Output Status Information LED 7 RS232 TX RX Connections 22 Digital Input Status Information LED...

Page 9: ...tions 17 USB Port 5 RS485 Port 1 Connections 18 Digital Output Status Information LED 6 RS485 Port 2 Connections 19 Digital Input Status Information LED 7 RS422 Connections 20 System Power LED 8 RS232...

Page 10: ...on 19 USB Port 5 RS485 Connections 20 Relay Status Information LED 6 N A 21 Digital Output Status Information LED 7 RS485 2 Connections 22 Digital Input Status Information LED 8 N A 23 System Power LE...

Page 11: ...ay Status Information LED 6 RS232 GND Connections 21 Digital Output Status Information LED 7 RS232 TX RX Connections 22 Digital Input Status Information LED 8 N A 23 System Power LED 9 N A 24 System R...

Page 12: ...19 USB Port 5 RS485 Connections 20 N A 6 RS232 GND Connections 21 Digital Output Status Information LED 7 RS232 TX RX Connections 22 Digital Input Status Information LED 8 N A 23 System Power LED 9 N...

Page 13: ...Connection 19 USB Port 5 RS485 Connections 20 N A 6 N A 21 Digital Output Status Information LED 7 RS485 2 Connections 22 Digital Input Status Information LED 8 N A 23 System Power LED 9 N A 24 Syste...

Page 14: ...y Output 4 Channel 3A 30VDC 5A 250VAC 4 Ch Enviromental Conditions Operating Temperature 25 75 C Storage Temperature 30 85 C Humidity 5 95 RH Operating Altitude 0 2000 m Memory SD Card Support Micro S...

Page 15: ...14 RTU300 SERIES HARDWARE MANUAL 1 8 Power Connection Diagram 1 8 1 Supply Connection Board Type GA1 GA2 GA4 GA5 GA6 GA7 Supply 12 36 VDC Protected Power 13 W Figure 9 RTU300 Power Connection Diagram...

Page 16: ...A1 GA2 GA4 GA5 GA6 GA7 Module Input 16 Channel PNP Voltage Range 0 36V DC ON Voltage Level 12 36V DC OFF Voltage Level 0 10V DC Input Impedance 2M Isolation Optical OFF to ON Response 20 us ON to OFF...

Page 17: ...tal Outputs Board Type GA1 GA2 GA4 GA5 GA6 GA7 Module Output 8 Channel Mosfet Output Module Output Type PNP Transistor Voltage Range 12 36V DC Max Output Current 2A 30V DC Isolation Optical Figure 11...

Page 18: ...E MANUAL 1 11Relay Outputs Board Type GA1 GA4 GA5 Module Output 4 Channel Relay Contact Outputs NO Normally Open Contact Contact Max Current 3A 30VDC 5A 250VAC Isolation Dry Contact Figure 12 RTU300 R...

Page 19: ...el 4 Channel Analog Input Type 0 20 mA 4 20 mA 0 20 mA 4 20 mA 0 20 mA 4 20 mA Analog Input Resolution 16 Bit 16 Bit 12 Bit Analog Input Precision 1 Precision 1 Precision 1 Precision Common Input GND...

Page 20: ...Outputs Board Type GA1 GA4 Module Output 2 Channel Analog Output Type 0 20 mA 4 20 mA Analog Output Resolution 12 Bit Current Output Precision 1 Precision Common Output GND 1 GND 2 Point Common Figure...

Page 21: ...unt 1 Port 2 Port RS485 or 1 Port RS485 and 1 Port RS422 2 Port Maximum Slave Count Limited to Hardware Isolation ESD Protection 8 kV Direct 25 kV Air Discharge Communication Distance 1000 m Data Bits...

Page 22: ...Serial Port Board Type GA1 GA5 GA6 GA2 RS232 Port Count 1 Port 1 Port with flow control Communication Distance 10 m Data Bits 7 8 Stop Bits 1 2 Parity None Even Odd Baudrate 300 bps to 200 kbps Figure...