background image

MM136

Wireless Gate Entry Intercom

Wireless and Wired

Installation Instructions

Summary of Contents for MM136

Page 1: ...MM136 Wireless Gate Entry Intercom Wireless and Wired Installation Instructions...

Page 2: ...gramming the Keypad 11 Programming Interface 11 Program New Master Code 11 Program Add New Entry Code 11 Program Add New Temporary Entry Code 11 Delete An Entry Code 11 Delete ALL Entry Codes 12 Inter...

Page 3: ...OTE Never install the keypad portion of this unit where a person can reach through the gate to activate it or where a person can touch the gate while activating the keypad The recommended minimum dist...

Page 4: ...change after he has made the delivery This will prevent him from being able to regain access while still allowing those to whom you gave permanent entry codes full access After entering a valid code p...

Page 5: ...d to factory settings All codes are deleted Default master code is 1234 10 Battery Holder Use 4 AA batteries if hard wired power supply is not used If external power source is used the 4 AA batteries...

Page 6: ...box to power the system down 2 Enter the master code or an entry code but continue pressing the last digit Any programmed code will work a Example Press 1 2 3 and then hold down 4 3 While still holdi...

Page 7: ...you have not changed your opener s transmitter code from the factory setting see the Setting Your Personal Transmitter Code section in the gate openers manual then set the keypad DIP switches to match...

Page 8: ...hard wired communication between the keypad and gate opener using 16 gauge AWG stranded direct burial low voltage wire part no RB509 strip the wires back 3 16 and attach the wires to the terminal blo...

Page 9: ...switch ON Test the keypad by entering 1 2 3 4 Step 7 Program your Personal Master Code and any additional entry codes for a total of 25 entry codes you wish See Programming the Keypad section 1 2 ABC...

Page 10: ...RECEIVER COM COM CYCLE CLOSE SAFETY EXIT OPEN SHADOW LOOP CLOSE EDGE OPEN EDGE BLK GRN RED Connect the 1 wire from RELAY OUTPUT terminals on the keypad to the CYCLE terminal on the opener control boar...

Page 11: ...2 seconds before returning to normal operation without saving Example Key press sequence to add 3456 as a new entry code 1234 is the Master Code The round black dot is the PROGRAM button Program Add...

Page 12: ...OGRAM button Beeper beeps 3 times to confirm that the All Entry Codes are deleted Example Key press sequence to delete all entry codes from memory 1234 is the Master Code 1 2 3 4 0 7 The round black d...

Page 13: ...4 hours when unplugged from the transformer You can turn the unit OFF to conserve battery power but it will not receive a signal when OFF Remove the battery access cover using a small phillips head s...

Page 14: ...t IMPORTANT Place Intercoms through the home or office with at least 10 feet between them to prevent interference RELAY OUTPUT AC DC POWER IN 1 2 3 4 5 6 7 8 9 0 ID SET RESET JUMPER ID SET button ID S...

Page 15: ...ottom of the intercom base unit 3 Make sure the antenna to antenna distance between the keypad and the base unit is at least 30 feet 4 Reset the MASTER Intercom base unit s ID Code Batteries must be i...

Page 16: ...g two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operationof the device Le pr sent appareil est...