3
4.
Connect the
BLACK
to the terminal labeled
COMMON
, and the
BLUE
wire to terminal in
STEP 3
to open gate. See wiring diagrams to
the right for guidance on wiring the sensor to your
gate opener’s control board.
5.
Connect the
POWER INPUT
wires from the
Exit Wand Sensor (if not already connected to a
terminal on the board).
• Connect the
YELLOW
and
BRAIDED
GROUND
wires to the
(–) NEGATIVE
side of
power source (i.e. battery).
• Connect the
RED
wire to the
(+) POSITIVE
side of power source (i.e. battery).
TURN GATE OPENER
OFF
Connect the
BLACK
wire from the
SENSOR
CABLE
to one of the
COMMON
terminals on
the opener control board.
Connect the
RED
wire from the
SENSOR
CABLE
to the
AUX V+
terminal on the opener
control board.
Connect the
YELLOW
wire and
BRAIDED GROUND
wire from the
SENSOR
CABLE
to the
AUX V-
terminal
on the opener control board.
Connect the
BLUE
wire from the
SENSOR
CABLE
to the
EXIT
terminal on the opener
control board.
BLUE
RED
BRAIDED
BLACK
RECR
GRN
BLK
RED
EXIT
SAFETY
EDGE
CYCLE
COMMON
LINK
Connect the
BLUE
wire from
the
SENSOR
CABLE
to the
EXIT
terminal on
the opener
control board.
Connect the
RED
wire from the
SENSOR CABLE
to the
H AUX OUT
terminal on the
opener board.
Connect the
BLACK
wire,
YELLOW
wire and
BRAIDED GROUND
wire from the
SENSOR
CABLE
to one of the
COMMON
terminals on
the opener control board.
BLUE
BRAIDED
YELLOW
BLACK
AUX
OUT
SOLAR
INPUT
18VAC/
H L
RECEIVER
ALM
RCVR.
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN EDGE
COM
CONTROL INPUTS
CLOSE EDGE
Connect the
BLUE
wire from
the
SENSOR CABLE
to the
EXIT
terminal on the opener
control board.
Connect the
BLACK
wire
from the
SENSOR CABLE
to one of the
COMMON
terminals on the opener
control board.
BLUE
BLACK
See the diagram to the left for battery connection instructions
for the RED, YELLOW AND BRAIDED GROUND wires.
WIRING DIAGRAM EXAMPLES
NOTE:
Power Input Connections Not Shown.
(See gate instruction manual for complete instructions)
BRAIDED GROUND
from
SENSOR
Cable
YELLOW
wire from
SENSOR CABLE
RED
wire from
SENSOR
Cable
Battery Cable
BLACK (-)
BLACK BATTERY CONNECTION WIRE
with Spade Connector included with
SENSOR
RED BATTERY CONNECTION WIRE
with Spade Connector included
with
SENSOR
Double Spade Connectors
included with
SENSOR
Battery Cable
RED (+)
VAR5
K1
PF1
K2
BA
TT
+
K3
K4
VAR4
VAR3
VAR2
VAR1
SFTY
.
EXIT
CYCLE
EDGE
SENSOR
COMMON
LOCK+
LOCK–
WHT
GRN
RED
BLK
WHT
GRN
SECOND OPR.
FIRST OPR.
RED
BLK
14 V
AC
OR
SOLAR
Connect the
BLUE
wire from
the
SENSOR
CABLE
to the
EXIT
terminal on the opener
control board.
Connect the
RED
wire from the
SENSOR
CABLE
to the
LOCK+
terminal on the opener control
board.
Connect the
BLACK
wire,
YELLOW
wire and
BRAIDED
GROUND
wire
from the
SENSOR
CABLE
to one of the
COMMON
terminals on the
opener control board.
BLUE
RED
BRAIDED
YELLOW
BLACK
Connect the
BLUE
wire from
the
SENSOR
CABLE
to the
EXIT
terminal on the opener
control board.
Connect the
BLACK
wire,
YELLOW
wire and
BRAIDED GROUND
wire to one of the
COMMON
terminals on the opener control board.
Connect the
RED
wire from
the
SENSOR
CABLE
to the
LOCK+
terminal
on the opener
control board.
POWER
CHGR
CHGR
EDGE
CY
CLE
EXIT
SAFETY
COM
COM
LOCK+
LOCK -
BLUE
BLACK
BRAIDED
YELLOW
IMPORTANT
WHEN THE WAND IS FIRST POWERED
UP IT MUST BE UNDISTURBED FOR 60
SECONDS TO PERFORM THE SELF TEST
AND CALIBRATIONS. BEFORE POWERING
THE WAND MAKE SURE THERE ARE NO
MOVING METAL OBJECTS OR MOVING
VEHICLES WITHIN THE RANGE OF
THE WAND
6.
Turn opener
ON
and
TEST
.