4.

 

Connect the 

BLACK

  to the terminal labeled 

 

COMMON

, and the 

BLUE

 wire to terminal in 

 

STEP 3 

to open gate. See wiring diagrams to 

the right for guidance on wiring the sensor to your 
gate opener’s control board.

5.

 

Connect the 

POWER INPUT

 wires from the 

Exit Wand Sensor (if not already connected to a 
terminal on the board).
•  Connect the 

YELLOW 

and 

BRAIDED 

GROUND

 

wires to the 

(–) NEGATIVE

 side of 

power source (i.e. battery).

•  Connect the 

RED 

wire to the 

(+) POSITIVE

 

side of power source (i.e. battery).

TURN GATE OPENER 

OFF

Connect the 

BLACK

wire from the 

SENSOR

CABLE

 to one of the

COMMON

 terminals on 

the opener control board.

Connect the 

RED

wire from the 

SENSOR

CABLE

 to the 

AUX V+

 

terminal on the opener 

control board.

Connect the 

YELLOW

wire and 

BRAIDED GROUND

 

wire from the 

SENSOR 

CABLE

 to the 

AUX V-

 terminal 

on the opener control board.

Connect the 

BLUE

 

wire from the 

SENSOR 

CABLE

 to the 

EXIT

 

terminal on the opener 

control board.

 BLUE 

 

RED

 

 

BRAIDED

BLACK

RECR

GRN

BLK

RED

EXIT

SAFETY

EDGE

CYCLE

COMMON

LINK

Connect the 

BLUE

 wire from 

the 

SENSOR 

CABLE 

to the 

EXIT

 terminal on 

the opener 

control board.

Connect the 

RED

 

wire from the 

SENSOR CABLE 

to the 

H AUX OUT

 

terminal on the 

opener board.

Connect the 

BLACK

 

wire, 

YELLOW

 wire and 

BRAIDED GROUND

 

wire from the 

SENSOR 

CABLE

 to one of the 

COMMON

 terminals on 

the opener control board.

 

BLUE

 

BRAIDED

YELLOW

BLACK

AUX

OUT

SOLAR

INPUT

18VAC/

H       L

RECEIVER

ALM

RCVR.

COM

GRN

BLK

RED

CYCLE

SAFETY

EXIT

SHADOW

OPEN EDGE

COM

CONTROL INPUTS

CLOSE EDGE

Connect the 

BLUE

 wire from 

the 

SENSOR CABLE 

to the 

EXIT

 terminal on the opener 

control board.

Connect the 

BLACK

 wire 

from the 

SENSOR CABLE 

to one of the 

COMMON

 

terminals on the opener 

control board.

BLUE

BLACK

See the diagram to the left for battery connection instructions 
for the RED, YELLOW AND BRAIDED GROUND wires.

WIRING DIAGRAM EXAMPLES

NOTE:

 Power Input Connections Not Shown.

(See gate instruction manual for complete instructions)

BRAIDED GROUND

from 

SENSOR

 Cable

YELLOW

 wire from 

SENSOR CABLE

RED

 wire from 

SENSOR

 Cable

Battery Cable

     

BLACK (-)

BLACK BATTERY CONNECTION WIRE

with Spade Connector included with 

SENSOR

 

RED BATTERY CONNECTION WIRE

with Spade Connector included 
with 

SENSOR

 

Double Spade Connectors

included with 

SENSOR

Battery Cable

    

RED (+)

VAR5

K1

PF1

K2

BA

TT 

+

K3

K4

VAR4

VAR3

VAR2

VAR1

SFTY

.

EXIT

CYCLE

EDGE

SENSOR

COMMON

LOCK+

LOCK–

WHT

GRN

RED

BLK

WHT

GRN

SECOND OPR.

FIRST OPR.

RED

BLK

14 V

AC

OR   

SOLAR

Connect the 

BLUE

  wire from 

the 

SENSOR

 

CABLE

 to the 

EXIT

 terminal on the opener 

control board.

Connect the 

RED

 wire from the 

SENSOR

 

CABLE

 to the 

LOCK+

 

terminal on the opener control 

board.

Connect the 

BLACK

 wire, 

YELLOW

 wire and 

BRAIDED 

GROUND

 wire

 

from the 

SENSOR

 

CABLE

 to one of the 

COMMON

 terminals on the 

opener control board.

BLUE

RED

BRAIDED

YELLOW

BLACK

Connect the 

BLUE

 wire from 

the 

SENSOR

 

CABLE

 to the 

EXIT

 terminal on the opener 

control board.

Connect the 

BLACK

 wire, 

YELLOW

 wire and 

BRAIDED GROUND

 

wire to one of the 

COMMON

 terminals on the opener control board.

Connect the 

RED

 wire from 

the 

SENSOR 

CABLE

 to the 

LOCK+

 terminal 

on the opener 

control board.

POWER

CHGR

CHGR

EDGE

CY

CLE

EXIT

SAFETY

COM

COM

LOCK+

LOCK -

BLUE

BLACK

BRAIDED

YELLOW

IMPORTANT

WHEN THE WAND IS FIRST POWERED 
UP IT MUST BE UNDISTURBED FOR 60 
SECONDS TO PERFORM THE SELF TEST 
AND CALIBRATIONS. BEFORE POWERING 
THE WAND MAKE SURE THERE ARE NO 
MOVING METAL OBJECTS OR MOVING 
VEHICLES WITHIN THE RANGE OF  
THE WAND

6.

 Turn opener 

ON

 and 

TEST

.

Reviews: