SPECIFICATIONS
INPUT RANGE
select
any
range from
0 to 10 Hz min
to 0 to 60 kHz max
INPUT SENSITIVITY
any
voltage from 50 mV
to 100 V peak
INPUT IMPEDANCE
100 kilohms
OUTPUT RANGE
Voltage
select
any
range from
–10 V to +15 V,
10 mA max load
(min span 0.2 V)
Current
select
any
range from
0 to 20 mA max
24 V compliance*
(min span 1 mA)
ACCURACY
±0.1% of span
LINEARITY
±0.1% of span
COMMON MODE REJECTION
120 dB, DC to 60 Hz
ISOLATION (ISO OPTION)
Output/Input
>500 megohms
Breakdown Voltage
>1000 VAC rms
BREAKDOWN,
PWR/CIRCUITRY
>1500 VAC rms
OPERATING TEMPERATURE
14°F to 140°F
–10°C to 60°C
TEMPERATURE STABILITY
±0.02% of span/°C max
OPTION P
Pullup resistor to + input
10 kilohms to +5 VDC
Open-circuit voltage
+5 VDC
POWER
115 VAC ±10%,
50 or 60 Hz
(2.5 W max)
230 VAC ±10%,
50 or 60 Hz
(2.5 W max)
(DC Power Option)
12 VDC
(limits 10 VDC to 15 VDC)
(2.5 W max)
24 VDC
(limits 21 VDC to 32 VDC)
(2.5 W max)
Isolation, DC power
supply to input
common: >500 megohms
*
Compliance: The sum of all
voltage drops in the output loop
cannot exceed 24 V at rated
current (1200 ohms @ 20 mA).
Specifications are subject to change without notice. ©2007 Wilkerson Instrument Co., Inc. DWG#W101041D 3/07
3
4