17
Technical data
EC DECLARATION OF CONFORMITY
MIGATRONIC A/S
Aggersundvej 33
9690 Fjerritslev
Denmark
hereby declare that our machine as stated below
Type: PI ROBO
conforms to directives: 2014/35/EU
2014/30/EU
2011/65/EU
European standards:
EN/IEC60974-1
EN/IEC60974-2
EN/IEC60974-3
EN/IEC60974-10 (Class A)
Issued in Fjerritslev 17.05.2017
Niels Jørn Jakobsen
CEO
1)
S
This machine meets the demand made for machines which are to operate in areas with increased hazard of electric chocks.
2) Equipment marked IP23S is designed for indoor and outdoor applications.
POWER SOURCE
PI 500 ROBO AC
PI 500 ROBO DC
Mains voltage ±15% (50Hz-60Hz), V
3x400
3x400
Minimum generator size, kVA
36
35
Fuse, A
32
32
Mains current, effective, A
27.2
26.1
Mains current, max., A
35.1
33.7
Power, (100%), kVA
18.8
18.1
Power, max, kVA
24.2
23.3
Power open circuit, W
40
40
Efficiency
0.87
0.91
Power factor
0.89
0.93
Current range MMA, A
Current range TIG, A
5-500
5-500
5-500
5-500
100% duty cycle at 20°C TIG, A
100% duty cycle at 20°C MMA, A
475
475
475
475
max. duty cycle at 20°C TIG, A/%
max. duty cycle at 20°C MMA, A/%
500/80
500/65
500/80
500/80
100% duty cycle at 40°C TIG, A/V
100% duty cycle at 40°C MMA, A/V
420/26.8
420/36.8
420/26.8
420/36.8
60% duty cycle at 40°C TIG, A/V
60% duty cycle at 40°C MMA, A/V
500/30.0
450/38.0
500/30.0
450/38.0
max. duty cycle at 40°C TIG, A/%/V
max. duty cycle at 40°C MMA, A/%/V
500/60/30.0
500/40/40.0
500/60/30.0
500/40/40.0
Open circuit voltage, V
95
95
1
Application class
S/CE
S/CE
2
Protection class
IP23S
IP23S
Standards
EN/IEC60974-1.
EN/IEC60974-2.
EN/IEC60974-3.
EN/IEC60974-10
EN60974-1.
EN60974-2.
EN60974-3.
EN60974-10
Dimensions (hxwxl), mm
1000x410x685
1000x410x685
Weight, kg
80
59.50
FUNCTION
PROCESS
VALUE RANGE
Arc-power, %
Electrode
0-100
Hot-start, %
Electrode
0-100
Anti-freeze
TIG/Electrode
always on
Start AMP, %
TIG
1-200
Stop AMP, %
TIG
1-90
Slope-up, sec.
TIG
0-20
Slope-down, sec.
TIG
0-20
Gas pre-flow, sec.
TIG
0-10
Gas post-flow, sec.
TIG
0-20
Spot welding time, sec.
TIG
0-600
Pulse time, sec.
MMA
0.01-10.0
Pause time, sec.
MMA
0.01-10.0
Base AMP, %
MMA
10-90
Second current (Bilevel), %
TIG
10-200
Shield gas flow, l/min
TIG
5-27
TIG-ignition
TIG
HF/LIFTIG
2/4 times triggermode
TIG
2/4
COOLING UNIT
Cooling efficiency (1 l/min), W
1650
Cooling efficiency (1,5 l/min), W
1900
Tank capacity, liter
3.5
Flow, bar - °C - l/min
3.0 - 60 - 1.5
Pressure max., bar
4.5
Standard
EN/IEC60974-2
Summary of Contents for PI 500 ROBO
Page 10: ...10 ...
Page 18: ...18 ...
Page 26: ...26 ...
Page 34: ...34 ...
Page 42: ...42 ...
Page 50: ...50 ...
Page 58: ...58 ...
Page 66: ...66 ...
Page 74: ...74 ...
Page 75: ...75 RESERVEDELSLISTE SPARE PARTS LIST ERSATZTEILLISTE LISTE DES PIÈCES DE RECHANGE ...
Page 79: ...79 ...
Page 85: ......