22
TECHNICAL DATA
POWER SOURCE
FLEX
2
3000 C
Mains voltage ±15% (50-60Hz)
3x400 V
Fuse
16 A
Mains current, effective
16.5 A
Mains current, max..
19.0 A (380V) / 18.1 A (400V)
Power, 100%
10.9 kVA
Power, max.
12.5 kVA
No load consumption
40 VA
Efficiency
0.85
Power factor
0.90
Current range
15-300 A
Duty cycle 20°C (MIG)
300A/100%
Duty cycle 40°C (MIG)
270A/100%
Duty cycle 40°C (MIG)
300A/80%
Open circuit voltage
69-76 V
1
Sphere of application
S
2
Protection class
IP 23
Standards
EN/IEC60974-1
EN/IEC60974-2
EN/IEC60974-5
EN/IEC60974-10 (Class A)
Dimensions (HxWxL) air cooled/water cooled
90.6x52.4x92.5 cm/105.1x52.4x92.5 cm
Weight air cooled/water cooled
58 kg/69 kg
WIRE FEED UNIT INTERNAL
COOLING UNIT
Wire feed speed
0.5-30 m/min
Cooling efficiency (1.0 l. flow)
1100W (1.0 l/min)
Torch connection
EURO connection
Tank capacity
3.5 litres
Wire-reel diameter
300 mm
Flow 1.2 bar – 60°C
1.75 l/min
Duty cycle 40°C
420A/100%
Pressure max..
3 bar
Duty cycle 40°C
500A/60%
Standards
EN/IEC60974-2
2
Protection class
IP 23
Wire diameter
0.6-2.4 mm
Gas pressure max.
0.5 MPa (5.0 bar)
Standards
EN/IEC60974-5
EN/IEC60974-10 (Class A)
FUNCTION
PROCESS
VALUE RANGE
Selection of trigger mode
MIG/MAG
2-times/4-times
Control of current/voltage/ wire feed speed
-
local/torch control/remote control
Wire inching
MIG/MAG
Yes
Torch cooling
-
water cooled/gas cooled
Hot-start %
MMA
0.0% – 100.0%
Hot-start-time
MMA
0.0 – 20.0 s
Arc power
MMA
0.0 – 150.0%
Gas pre-flow
MIG/MAG
0.0 – 10.0 s
Soft-start
MIG/MAG
0.5 – 24.0 m/min
Hot-start
Synergic
-99% – +99%
Hot-start-time
Synergic
0.0 – 20.0 s
Slope down
Synergic
0.0 – 10.0 s
Stop Amp
Synergic
0 – 100%
Stop Amp time
Synergic
0.0-10.0 s
Burn back
MIG/MAG
0 – 30
Gas post-flow
MIG/MAG
0.0 – 20.0 s
Sequence timer / Spot welding time
MIG/MAG
0.0 – 50.0 s
DUO Plus
TM
efficiency
MIG/MAG
0 – 50%
DUO Plus
TM
time
MIG/MAG
0.1 – 9.9 s
Electronic choke
-5.0 – +5.0
Sequence
9 sequence steps
1
S
This machine meets the demand made for machines which are to operate in areas with increased hazard of electric chocks
2
Equipment marked
IP23
is designed for indoor and outdoor applications
Summary of Contents for FLEX2 3000 Compact
Page 16: ...16 ...
Page 30: ...30 ...
Page 58: ...58 ...
Page 72: ...72 ...
Page 86: ...86 ...
Page 100: ...100 ...
Page 114: ...114 ...
Page 128: ...128 ...
Page 142: ...142 ...
Page 159: ... ...