background image

 

- 14 - 

<Table 4> 

No. 

Matters 

Code 

Component name 

Qty 

Dimensions 

(mm)/Model 

Remark 

301110001 

Adjustable steel 

legs 

φ41.5*100 

C-HP-2-12-NG(LP) 
C-HP-4-24-NG(LP) 
C-HP-6-36-NG(LP) 

21103001014 

Catch tray 

507*620*26.5 

C-HP-2-12-NG(LP) 

21103002014 

807*620*26.5 

C-HP-4-24-NG(LP) 

21103003014 

1107*620*26.5 

C-HP-6-36-NG(LP) 

301081006 

Galvanized 

American outside 

six corner with pad 

tapping 

30 

ST4.8*12.5 

C-HP-2-12-NG(LP) 
C-HP-4-24-NG(LP) 
C-HP-6-36-NG(LP) 

301140001 

Kirsite knob 

 

C-HP-2-12-NG(LP) 

C-HP-4-24-NG(LP) 

C-HP-6-36-NG(LP) 

21103001033 

Control panel 

605*185 

C-HP-2-12-NG(LP) 

21103002027 

905*185 

C-HP-4-24-NG(LP) 

21103003021 

1205*185 

C-HP-6-36-NG(LP) 

21205001002 
21205002002 
21205003002 

surround 

310*640*203 

 

C-HP-2-12-NG(LP) 

610*640*203 

 

C-HP-4-24-NG(LP) 

910*640*203 

C-HP-6-36-NG(LP) 

301030002 

A18 stopcock 

A18-318 

C-HP-2-12-NG(LP) 

C-HP-4-24-NG(LP) 

C-HP-6-36-NG(LP) 

301040004 
301040005 

A18 nozzle(NG) 
A18 nozzle(LP) 

NG43 
LP53 

C-HP-2-12-NG(LP) 

C-HP-4-24-NG(LP) 

C-HP-6-36-NG(LP) 

301030007 

Pilot light 

valve-double unit 

AP6-1 

C-HP-2-12-NG(LP) 

C-HP-4-24-NG(LP) 

C-HP-6-36-NG(LP) 

Summary of Contents for C-HP-2-12-LP

Page 1: ...ktops Operating Instructions Before you begin please read these instructions carefully to use this product correctly to make the product perform ideally and to avoid hazards Models C HP 2 12 NG LP C H...

Page 2: ...anual in a safe place for convenient reference and operation This instruction manual is subject to any change without further notice and the manufacturer reserves the right of final interpretation The...

Page 3: ...n 3 2 Brief Instruction 3 3 Manufacture s Authority and Responsibility 3 4 Parameter Specifications 4 5 Transport and Storage 6 6 Installation and Debugging 6 7 Safety Notices and Precautions 8 8 Oper...

Page 4: ...struction The product is a series of gas char broilers in our company production which is novel designed reasonable structured convenient operated durable used and convenient maintained It s equipped...

Page 5: ...4 4 Parameter Specifications 4 1 Outline Dimensions in C HP 2 12 NG LP C HP 4 24 NG LP...

Page 6: ...of burners and control method Gas Species Intake tube pressure in W C Per BTU B T U h Total BTU B T U h Nozzle No C HP 2 12 NG LP 2 pieces Independent control Natural Gas 4 25 000 50 000 43 L P Gas 1...

Page 7: ...acking and Installation Please dispose of all packaging materials and residues after unpacking Check the equipment If it is damaged please keep wrappers and receipts which must be signed by the carrie...

Page 8: ...um gases Warning Use soap water or testing instrument to test whether piping joint leaks or not before using and forbid using an open flame to test After installing completely you should check gas sup...

Page 9: ...ch During operation do not directly touch burners and cooking grates Turn off the equipment as repairing maintaining and cleaning If the equipment has any problems of equipment damage gas piping leaks...

Page 10: ...light then the main fire burner is lighted by the pilot light The power of burner increases as revolving angel increases When knob reaches to burner is in the maximum power Fig 4 Fig 2 Fig 3 Fig 4 Ma...

Page 11: ...ut adjustment but only switching gas Adjust only by authorized and licensed technicians When you converse the gas source exchange the corresponding pressure maintaining valve which installed on air in...

Page 12: ...censed technicians The product is made of 90 metals and can not be discarded everywhere Deal with it in accordance with the local codes Instructions to clean appliance regularly with recommended clean...

Page 13: ...rd a sound of fire 1 Insufficient gas pressure in pipe 1 Contact the local gas supply dept 2 Not match nozzle aperture with gas resources 2 Adjust nozzle diameter 3 Flow of connection pipe is not enou...

Page 14: ...other companies our company has the right not to provide warranty service Order replacement parts from authorized representatives and after sale service agency Provide the model number serial number...

Page 15: ...01140001 Kirsite knob 2 C HP 2 12 NG LP 4 C HP 4 24 NG LP 6 C HP 6 36 NG LP 5 21103001033 Control panel 1 605 185 C HP 2 12 NG LP 21103002027 905 185 C HP 4 24 NG LP 21103003021 1205 185 C HP 6 36 NG...

Page 16: ...5 301060002 Needle type pressure joint screw arbor 1 M5 23 C HP 2 12 NG LP C HP 4 24 NG LP C HP 6 36 NG LP 16 301990001 Damper cover 2 C HP 2 12 NG LP 4 C HP 4 24 NG LP 6 C HP 6 36 NG LP 17 301081002...

Page 17: ...1015 Burner back plate 1 607 76 71 C HP 2 12 NG LP 2 C HP 4 24 NG LP 3 C HP 6 36 NG LP 27 21203001001 Unit 1 310 700 37 C HP 2 12 NG LP 21203002001 610 700 37 C HP 4 24 NG LP 21203003001 910 700 37 C...

Page 18: ...maintaining valve connects with air intake must be installed by authorized and licensed technicians to ensure interface tightness 2 Screw the hex nut Fig 9 before connect air intake ensure gas mark Fi...

Page 19: ...vantages of good durability and low maintenance charge But to update some components and necessary maintenance can prolong life length of the products Contact the dealer for assistance In order to avo...

Reviews: