intake-tube is 3/4 inches.
<Table 1>
Model
#of
burners
and
control
method
Gas
Species
Intake-
tube
pressure
(in.W.C.(
Per
BTU
B.T.U./
h
Total
BTU
B.T.U./h
Nozzl
e No.
C-G24-
NG(LP)
2 pieces
Independe
nt control
Natural
Gas
4
30,000
60,000
#37
L.P. Gas
10
30,000
60,000
#51
C-G36-
NG(LP)
3 pieces
Independe
nt control
Natural
Gas
4
30,000
90,000
#37
L.P. Gas
10
30,000
90,000
#51
C-G48-
NG(LP)
4 pieces
Independe
nt control
Natural
Gas
4
30,000
120,000
#37
L.P. Gas
10
30,000
120,000
#51
5. Transport and Storage
In the process of transportation, handle carefully and keep upright
to prevent damage of the product packing. Wrapped equipment should
not be in open air for a long time, and shall be placed in a well-
ventilated and non-corrosive gases warehouse. When equipment needs
temporary storage, waterproof measures should be taken.
6. Installation and Debugging
Any erroneous installation, adjustment, refit, overhaul or
maintenance may cause property damage or personal injury.
The work shall be performed by authorized and licensed
technicians, otherwise the manufacturer has the right not to
provide warranty service;
Only be installed in accordance with the local code. If no
similar standard, you should conform to the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, the National Gas Installation Code,
CSA-B149.1, or the L.P. Gas Installation Code, CSA-B149.2 as
applicable;
The appliance individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing
of that system at test pressures in excess of 1/2psi (3.45kPa).
6.1:Unpacking and Installation
Please dispose of all packaging materials and residues after