h5
c
lmax
b
l2
l3
l1
Ød
is
o
g1
g2
g5
g4
g6
g3
a
a,b
h2
h4
h6
Ød
Ød
Ød
h1
a,b
e4
e5
e1
h
28
MIETZSCH GmbH Lufttechnik Dresden
Großenhainer Str. 137
01129 Dresden
Fax (0351) 8 58 00 74
http://www.mietzsch.de
Radial fans of plastic material
VRE 100 ... 250
(special materials)
Dimensions
Casing connection - suction side
Casing connection-pressure side
R_ rigid connection, rectangular
flange welded on
and undrilled/drilled
1)
KOR_ elastic connection,
rectangular
compensator welded on
flange undrilled/drilled
1)
RSF_ rigid connection, round
transition, flange welded on
and undrilled/drilled 1)
KOF_ elastic connection, round
transition
compensator welded on
flange undrilled/drilled 1)
ELA elastic connection, round
transition
connecting element of
flexible PVC
fastened with band clamp
MAIN DIMENSIONS
In case of special materials (PE, PVDF, electrically
conductive materials) casings of sizes 100 … 250 consist
of two even side walls and one jacket welded together.
The dimension sketch shows
housing position 090R
.
For other positions the manufacturers turn the casing
around the fan axis.
The smooth connection on the suction side has diameter
d = nominal diameter. The smooth connection on the
pressure side is rectangular a x b. Many connection
variants are possible to meet customers' demands.
Design version ELA, vibration isolators, and a
condensate bore with closing cap are elements of the
standard range of delivery. Other versions have to be
ordered separately.
Drawings in format dxf --> MIETZSCH-CD
Housing position
090R
1) Flanges (round) and frames (rectangular) are made according to MIETZSCH standard MWS 53030.
Drilling pattern:
0 undrilled (such as FO, KOFO)
1 drilled according to series 1 for normal applications (such as KOF1)
2 drilled according to series 2 (double number of screws) for high pressures and large quantities of
condensate (such as F2, KOF2)
l and h are functional dimensions applying to the
corresponding casing connection.
In the case of KOF, for instance, the distance fan
axis/flange amounts to c + I2 or g5 +
h6
.
F_
rigid
connection,
round
flan
ge wel
de
d
on
a
nd
un
dr
ill
ed
/dr
ill
ed
1)
K
O
F
_ elast
ic con
n
ect
io
n
, ro
un
d
c
om
pe
ns
ato
r we
ld
ed
on
flan
ge und
ril
le
d/d
ril
le
d
1)
EL
A
elast
ic con
n
ect
io
n,
rou
n
d
c
on
nec
ting
el
em
en
t o
f fl
ex
ib
le
P
V
C
, wi
th
ba
nd
cl
am
p
i_v
re_
en
(
09/
06)
Fan dimensions
Fan size
Ø d
a
b
c
e1
e3
e4
e5
g1
g2
g3
g4
g5
g6
h
hiso lmax
VRE 100
110
96
102
105
204
198
-40
50
144
109
119
120
145
178
240
20
510
VRE 160
160
144
152
141
274
310
4
60
222
168
179
194
190
264
332
20
685
VRE 200
200
180
187
169
306
370
17
70
278
210
224
240
240
330
395
20
730
VRE 250
250
226
236
203
332
480
52
110
346
264
280
298
290
412
460
25
890
Dimensions for casing connections
Fan size
Ø d
a
b
l1
l2
l3
h1
h2
h4
h5
h6
VRE 100
110
96
102
60
70
4
4
135
104
225
235
VRE 160
160
144
152
125
135
5
5
135
135
255
265
VRE 200
200
180
187
125
135
5
5
135
155
275
285
VRE 250
250
226
236
125
135
5
5
135
205
325
335