![Miele XCI-Box-LG Operating And Installation Instructions Download Page 38](http://html.mh-extra.com/html/miele/xci-box-lg/xci-box-lg_operating-and-installation-instructions_234119038.webp)
en - English
38
Current carrying capacity table
App
lication
Terminal
assign
ment
Signal
Signal
direction
Current
carrying
capacity
Description
PE
Protective earth
PE
Protective earth
PE
Protective earth
PE
Protective earth
P
eak load
(DIN 18875)
1.1
L'
a Switch-on signal
1.2
L'
b Heating demand
1.3
L'
c Heating enable
1.4
N'
d Neutral conductor
P
ayment syst
em
2.1
L'
Appliance ready for operation
2.2
L'
Programme status
2.3
L'
Programme buying impulse
2.4
N'
Time buying signal
2.5
N'
Power supply
2.6
L
Power supply
PWM (washing machine): dispensing
PDR (dr
yer): additional components
3.1
N'
1.0 A
Ext. power supply
3.2
L
1.0 A
Ext. power supply
3.3
L'
4.0 A
Dispensing 1/Additional fan
3.4
N'
4.0 A
Power supply
3.5
L'
1.0 A
Dispensing 2/Exhaust valve
3.6
N'
1.0 A
Power supply
3.7
L'
1.0 A
Dispensing 3/Indicator light/Buzzer
3.8
N'
1.0 A
Power supply
3.9
L'
1.0 A
Dispensing 4
3.10
N'
1.0 A
Power supply
3.11
L'
1.0 A
Dispensing 5
3.12
N'
1.0 A
Power supply
3.13
L'
1.0 A
Dispensing 6
3.14
N'
1.0 A
Power supply
4.1
+13 V
Empty sensor*
4.2
Empty sensor*
5.1
Coding
5.2
Coding
L' = switched phase, N' = switched neutral conductor
* see section “Current carrying capacity of the inputs and outputs”
Total current load of electronic module: see section “Installation”.